21
a.
The red indicator in the ON/OFF switch lights.
b.
The steam generator fills with water.
c.
The burner does NOT light.
6. Turn ON the ON/OFF switch.
a.
The igniter initiates a spark and gas is supplied to the pilot for 90 seconds.
b.
If the pilot does not light in 90 seconds, then the ignition system locks out.
•
Reset system by waiting 5 minutes OR
•
Turn the ON/OFF switch OFF and back ON.
•
If the burner does NOT light after two attempts, go to Step 8.
7. When the burner lights, the steam generator begins heating.
a.
The Heat Standby feature cycles the burners on and off to maintain operating temperature if
the cooking compartments are not in use.
•
The Heat Standby Feature will turn the burners on every 6 minutes for 20 seconds as
long as the steamer is ON and has water in it and the cooking compartments are off or
the appliance is in Timed mode with the Timers at 0.
•
Do not work near or above the exhaust flue whenever power is on.
•
There is no warning to Heat Standby burner ignition.
b.
The appliance is ready to cook.
1) End this test here and go to the Shutdown Instructions.
8. If the burner does not light: Wait 5 minutes and then repeat Steps 2-6 up to three more times.
•
EITHER:
If the burner does NOT light after repeating Steps 2-6 four times, go to the
Shutdown Instructions and call a qualified Cleveland Range authorized service representative
to adjust the burner controls.
•
OR:
If the burner lights in four or less tries of Steps 2-6, go to Step 7.
B. Shutdown Instructions
1.
Turn OFF the electrical power to the appliance, at both the ON/OFF Switch and the Main External
Power Switch.
2.
Turn OFF the gas supply at Main Manual Gas Valve.