b. Ensure that the capacitance change during blowing is less than 50.
4. If the alarm is still reported, increase the servo drive gain as needed.
4.4.12 System Reports Material Collision Alarm when the System Has No Movement
Reason
The current capacitance is equal to or smaller than the
Touch Part Capacitance
value.
Solution
Follow the steps below to help troubleshoot:
1. Ensure that the machine and material colliding capacitance are correct.
If not, replace the machine and material colliding capacitors.
The normal machine capacitance for SE001 later than V1.4 is about 650,000 while
that for SE001 earlier than V1.4 is about 1.3 million.
2. Use a multimeter to measure the conductivity of the copper core between the cutter
nozzle and sensor.
If the conductivity is zero, the cutter is damaged.
3. Use a multimeter to measure the conductivity of the copper core between the cutter
nozzle and RF cable.
If the conductivity is zero, the RF cable is damaged.
4. Check to see if the resistance between the No.1 and No.2 ports of SE001 is 4.8
KΩ–5.3 KΩ (tolerance≤5%) and if the resistance between the No.2 and No.4 ports
is 0 Ω–1 Ω.
If not, SE001 is damaged. Replace it.
5. Measure the conductivity of the corresponding pins of the M16 three-core aviation
cable.
If the conductivity is zero, replace the cable.
6. If the alarm is still reported, replace the EX33A extension terminal board.
4.4.13 Follow Overshoot
Reason
The speed of servo drive response is slower than the command speed.
Solution
Follow the steps below to help troubleshoot:
1. Ensure that
Pulse Equivalent
,
Speed Gain
,
Pulse Counter Per Turn
are set
correctly.
2. Increase the servo drive gain.
3. Ensure matching between the Z axis maximum speed and dry run speed. The Z
axis dry run speed can be lowered by certain amount if needed.
Содержание LS6000M
Страница 6: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 3 116 1 3 Shortcut Keys The shortcut keys are as follows...
Страница 63: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 60 116 Lambda NE The port definitions are shown below...
Страница 69: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 66 116 5 2 5 MAX Fiber Laser The wiring diagram is shown below...
Страница 75: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 72 116 With brake lines 50P HD plug...
Страница 76: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 73 116 Without brake lines 50P HD plug...
Страница 78: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 75 116 One to two...
Страница 81: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 78 116 Fuji alpha5 plus axis X Y1 Y2...
Страница 83: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 80 116 Delta ASDA B...
Страница 84: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 81 116 Delta ASDA B one to two...
Страница 86: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 83 116 MR JE with brake cable...
Страница 87: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 84 116...
Страница 91: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 88 116 ESDA...
Страница 93: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 90 116 R series...
Страница 96: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 93 116 With brake lines 50P HD plug...
Страница 97: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 94 116 Without brake lines 44P interface...
Страница 105: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 102 116 Delta ASDA B2...
Страница 112: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 109 116 The button definitions are shown below...
Страница 114: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 111 116 The button definitions are shown below...
Страница 115: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 112 116...
Страница 117: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 114 116...