Specification
Seite 176 / 180
Inverter Model
V30
00-
015
NF/
HF
V30
00-
022
NF/
HF
V30
00-
037
NF/
HF
V30
00-
055
NF/
HF
V30
00-
075
NF/
HF
V30
00-
110
NF/
HF
V30
00-
150
NF/
HF
V30
00-
185
NF/
HF
V30
00-
220
NF/
HF
V30
00-
300
NF/
HF
V30
00-
370
NF/
HF
V30
00-
450
NF/
HF
V30
00-
550
NF/
HF
Control system
Sine-wave modulation PWM system
Output
frequency
range
0.1-400Hz
Frequency
accuracy
Digital c/-0.01% for Max. frequency, analog fre/-0.2%(25+-10C)
Frequency
resolving
power
Digital setting : 0.01Hz
Analog setting : Max. frequency/4000
Voltage/freque
ncy
characteristic
V/f option variable, V/f control, (constant torque, reduced torque), sensor-less vector
control (base frequency 30-400Hz)
Speed
fluctuation
+-0.5% (sensor-less vector control)
Overload
current rate
150% for 60 seconds
200% for 0.5 second
Acceleration/de
celeration time
0.01-3600.0 seconds (straight or S-Curve on acceleration, deceleration is optional setting
individually),
Stating torque
200
/0.5Hz (sensor-less vector control
150
/Ohz area torque (0Hz sensor-less vector control
At the time of 1 frame under motor
connection
DC Braking
On starting and decelerating by stop command, inverter operates under operation setting
frequency. Or inverter operates with external input
(Breaking power, time, frequency can be set.)
Operato
r
Setting by key.
Volume
DC 0 to 5V, -5 to +5V, 0 to 10V, -10 to +10V (input impedance 10k ohm), 4-20mA (input
impedance 100 ohm)
Fr
eq
u-e
nc
y
Extend
Signal
Setting with RS485 communication
Operato
r
Run/Stop
Volume Forward Run/Stop (1a connect), reverse command is impossible on assigning of terminal
(selection of 1a, 1b is possible), input of 3 wires is possible.
Ru
n/
St
op Extend
Signal
Setting with RS485 communication
Intelligent
input terminal
Use by selecting terminals from;
Reverse command (RV), multi-speed1-4 (CF1-CF4), jogging (JG), external dc braking
(DB), 2
nd
control (SET),2
nd
acceleration (2CH), free-run stop (FRS), external trip (EXT),
USP function (USP), commercial change (CS),software lock (SFT), analog input voltage /
current / select (AT), 3
rd
control (SET3) ,reset inverter (RS), 3 wire run (STA),3 wire keep
(STP),3 wire direction selection (F/R), PID selection valid/invalid (PID), PID integrating
reset (PIDC),control gain change (CAS) ,remote control,up function (UP), remote control
down function (DWN), remote control data clear (UDC), Compulsion operation(OPE)
multi-speed bit 1-7(SF1-SF7),overload ristriction change (OLR),torque limit exist or
no(TL),Torque limit change 1(TRQ1),Torque limit change 2(TRQ2),P/PI
change(P/PI),Brake confirmation (BOK) orientation(ORT)
LAD cancel(LAC)
Position
deviation clear (PCLR),90 degrees the phase difference permission (STAT) , permissive
input signal for FW/RV(ROK), no assign (NO)
Input
Thermistor
input terminal
1 terminal
1 2
Содержание V3000-015HF
Страница 1: ...INVERTER Series V3000 M A N U A L...
Страница 13: ...General Descriptions Seite 13 180 6 2 Dimension 178...
Страница 91: ...Explanation of Function Seite 91 180 Reduced rated ratio Inverter output Frequency X1 0 0 60 X0 9 X0 8 5 2 5...
Страница 173: ...Explanation of Function Seite 173 180 RB N No conduct N RB No conduct...
Страница 179: ...Specification Seite 179 180 V3000 150 220NF HF V3000 300NF HF 2 31 26 54 51 10 19 25 22 2 39 37 7 22 9 24 19 92...
Страница 180: ...Specification Seite 180 180 V3000 370 450NF HF V3000 550NF HF 25 55 52 10 39 30 2 25 70 67 12 48 38 2...