Содержание V3000-015HF

Страница 1: ...INVERTER Series V3000 M A N U A L...

Страница 2: ...ual provides you with the information necessary to install start up and operate the V3000 frequency converters It is recommended that this manual is read thoroughly before powering up the frequency co...

Страница 3: ...online de WATT DRIVE Nord GmbH D 51429 Bergisch Gladbach Vertriebs und Servicecenter K ln Tel 49 2204 84 2800 Fax 49 2204 84 2819 e mail watt koeln t online de WATT DRIVE D 97044 W rzburg Vertriebs un...

Страница 4: ...t avoided can result in serious injury or death COUTION CAUTION Indicates a potentially hazardous situation which if not avoided can result in minor to moderate injury or serious damage of product The...

Страница 5: ...e read and clearly understood before working on V3000 series equipment Proper grounds disconnecting devices and other safety devices and their location are the responsibility of the user and are not p...

Страница 6: ...et these specifications a Voltage fluctuation 10 or less b Voltage imbalance 3 or less c Frequency variation 4 or less d Voltage distortion THD 10 or less 2 Installation measure a Use a filter designe...

Страница 7: ...General Descriptions Seite 7 180 Revision History Table No Revision Contents The Date of Issue Operation Manual No 1 Initial Release of Manual NB611X Sep 1999 NB611X...

Страница 8: ...ower supply is off Otherwise there is a danger of electric shock and or injury p 2 5 Be sure to implement wiring after installing the body Otherwise there is a danger of electric shock and or injury p...

Страница 9: ...if the unit appears damaged There is a risk of injury p 2 1 Avoid locations of high temperatures high humidity dew condensation dust corrosive gases explosive gases combustible gases coolant mist and...

Страница 10: ...orrectly Otherwise there is the danger of fire p 2 5 Do not use the electromagnetic contactors to stop the Motor running always use the Inverters internal controls Otherwise there is the danger of inj...

Страница 11: ...ual 14 1 2 Question and Warranty of the Unit 15 1 2 1 Request upon asking 15 1 2 2 Warranty for the unit 15 1 3 Appearance 16 1 3 1 Appearance and Names of Parts 16 2 1 Installation 17 2 1 1 Installat...

Страница 12: ...S VECTOR CONTROL 138 Precautions 138 Communication function 145 4 4 Protection function list 164 4 4 1 Protection function 164 4 4 2 Trip monitor display 166 4 4 3 Warning Monitor display 167 5 1 Prec...

Страница 13: ...General Descriptions Seite 13 180 6 2 Dimension 178...

Страница 14: ...for the Inverter 3 Make sure that the product is the one you ordered by checking the specification label 1 1 2 Operation manual This operation manual is the manual for the WATT Inverter V3000 Series...

Страница 15: ...l or attempted repair by unauthorised personnel 2 Any damage sustained other than from transportation Which should be reported immediately 3 Using the unit beyond the limits of the specification 4 Act...

Страница 16: ...nce and Names of Parts Appearance from the front Connector Installation point of self contained option Control circuit Main circuit terminals Wiring blind cover Front cover removed POWER Alarm lamp Di...

Страница 17: ...and injury Do not allow substance of cutting waste sputtering of welding waste of iron wire and dust etc to come into contact with the unit It is a fire risk Make sure the surface the unit is installe...

Страница 18: ...reactor 3 Operating Environment Ambient Temperature The ambient temperature surrounding the Inverter should not exceed the allowable temperature range usually 10 to 50 C The temperature should be mea...

Страница 19: ...make sure that the temperature around is within the limit of the allowable range 8 External cooling of Inverter It is possible to install the inverter so that the heatsink is out of the back of the en...

Страница 20: ...or fire Otherwise there is a danger of electric shock and or injury Only qualified personnel shall carry out wiring work Otherwise there is a danger of electric shock and or fire Implement wiring aft...

Страница 21: ...h 400V DC 0 10V Output intelligent R S T RO TO U V W P PD RB N IM PLC P24 FW 7 6 1 8 FM CM1 TH H O O2 OI L AM AMI DC24V SP SN RP SN Option 1 Option 2 For terminal resistance RS485 Put and take as term...

Страница 22: ...is maximum frequency When only At terminal is ON this input signal is effective Input Impedance 100 ohm Allowable maximum current 24mA AM Digital monitor voltage Allowable maximum current 2mA AMI Ana...

Страница 23: ...r factor correction capacitors or a surge absorber to the output The inverter will trip or sustain damage to the capacitors or the surge absorber In the case of the cable length being more than 20 met...

Страница 24: ...erminals P N to terminals P N on the inverter The braking resistor is then wired into the External Braking unit and not directly to the Inverter The cable length should be less than 5 metres and twist...

Страница 25: ...r M6 V3000 150 185NF V3000 150 370HF Ro To M4 Other M6 V3000 300 370NF V3000 450 550HF Ro To M4 Other M8 V3000 220NF Ro To M4 Earth terminal M6 Other M8 S300 450 550LF Ro To M4 Earth terminal M8 Other...

Страница 26: ...es radiation noise emitted from wire at the input Direct reactor DCL This part control harmonic from inverter Breaking resistor Regenerative breaking unit This part is used for applications that need...

Страница 27: ...55 V3000 550LF 150 60x2 3 M10 150 1 0 RX400B 350A 250A H250 1 5 V3000 015HF 2 18 2 18 M4 2 4 1 5 EX30 10A 10A H10C 2 2 V3000 022HF 2 16 2 16 M4 2 4 1 5 EX30 10A 10A H10C 3 7 V3000 037HF 2 14 2 14 M4...

Страница 28: ...also switch off and the alarm output signal will not be held The power terminals Ro and To are designed to allow a supply to go direct to the control circuit and therefore keep the alarm output signal...

Страница 29: ...eparate the control circuit wiring from the main power and relay control wiring 5 If control and power wires must cross make sure they cross at 90 degrees to each other 6 When connecting a thermistor...

Страница 30: ...6 4 2 15 CM2 12 ALO AL2 3 Change of input logic type The logic type of intelligent input terminals is sink type Factory Default To change the input logic type into source type take off the short bar b...

Страница 31: ...the short bar of control terminal Sink type Inverter YTR48 type Output module Short bar DC24V S COM P24 PLC CM1 FW 8 DC24V P24 PLC CM1 FW S DC24V COM Inverter YTR48 type Output module 8 Source type In...

Страница 32: ...erminal are the voltage setting and the electric setting And they are selective by each system The control circuit terminal list shows this in detail Necessary things for operation 1 The operation set...

Страница 33: ...and terminal operator This is the method of inverter operating from both of the above two operating methods It is possible that the operation setting and the frequency setting can be selected for bot...

Страница 34: ...n code turns back to A001 4 Set terminal with the operation setting selection Set A002 as indication code press the key once Two figures are shown Set 01 with the key or the key press the key once to...

Страница 35: ...Operation Seite 35 180 Impress voltage between O and L of terminal to start operation 7 Input ending operation setting Turn OFF between FW and CM to stop slowly down...

Страница 36: ...are shown Set 02 with the key or the key press the key once to set the frequency setting for the operator Indication code turns back to A001 4 Set operator with the operation setting selection Set A00...

Страница 37: ...001 and press the key once Or when monitoring the operation direction set indication code to d003 press the key once Indication code are forward reverse or stop 8 Press the key to start operating The...

Страница 38: ...the digital operator OPE S V3000 series operates by using the digital operator which is fitted as standard 1 Name and contents of each part of the digital operator Monitor lamp Down key ALARM Power L...

Страница 39: ...Frequency V Voltage A Current kW Electric power Rate Operation command Display lamp Light on only when operating command RUN STOP is set in operator Run key Run command to start the motor But this is...

Страница 40: ...de is displayed The display will be Push the key 2 Display monitor code No Display d001 F U N C 4 Display extension function mode Push the key 1 2 Push the key 6 times 6 Return to the state of 2 5 Dis...

Страница 41: ...3 Refer to setting method of function code 1 Push the key Push the key 2 19 19 times 3 Display code No of basic setting mode 1 Extension function mode Display in the order of A b C H P U Push the 1 2...

Страница 42: ...pushing the STR key Operation command display lamp light will switch off so that operation command is now 5 Display extension function It is possible to shift to other extension function modes monito...

Страница 43: ...ish setting A029 Note When you input code No there isn t in the code list A of left end blinks again Confirm code No and input it again 6 Finish setting f nction Push the Key STR Decide 9 Push the key...

Страница 44: ...igure 0 blinks Don t change third figure and push the STR key and confirm 4 Change second figure of function code No Second figure 0 Push the STR Confirm 0 Second figures 2 1 Push the key 2 times Push...

Страница 45: ...ric power monitor 0 0 999 9 kW 4 15 d016 Accumulated time monitor during RUN 0 9999 1000 9999 100 999 hr 4 16 d017 Power ON time monitor 0 9999 1000 9999 100 999 hr 4 16 d080 Number of trip time monit...

Страница 46: ...n time 0 01 99 99 100 0 999 9 1000 3600 s 30 0 0 4 19 F30 3 3rd deceleration time 0 01 99 99 100 0 999 9 1000 3600 s 30 0 0 4 19 F00 4 Operation direction selection 00 forward 01 reverse 00 4 17 Note1...

Страница 47: ...ric power monitor 0 0 999 9 kW 4 15 d016 Accumulated time monitor during RUN 0 9999 1000 9999 100 999 hr 4 16 d017 Power ON time monitor 0 9999 1000 9999 100 999 hr 4 16 d080 Number of trip time monit...

Страница 48: ...n time 0 01 99 99 100 0 999 9 1000 3600 s 30 0 0 4 19 F30 3 3rd deceleration time 0 01 99 99 100 0 999 9 1000 3600 s 30 0 0 4 19 F00 4 Operation direction selection 00 forward 01 reverse 00 4 17 Note1...

Страница 49: ...tor Indication code d002 displays the output current value The data is displayed as follows In case of displaying d002 the monitor lamp A is illuminated Display 0 0 999 9 Display is in 0 1A unit Opera...

Страница 50: ...monitor part Feedback quantity x PID scale Frequency command value A075 Setting A071 0 1 PID is effective A075 0 01 99 99 Display is 0 01 99 99 Set with the 0 01 unit Display 0 00 99 99 Display is in...

Страница 51: ...or The LED display will monitor the state of the intelligent outputs Example Output intelligent terminal 12 11 ON Output alarm AL Output intelligent terminal 15 14 13 OFF d005 Intelligent input monito...

Страница 52: ...cy d001 50 00Hz When the frequency conversion factor b086 is 1 1 the frequency conversion monitor d007 displays 55 00 as 50 x 1 1 55 00 Output torque monitor This inverter displays the output torque e...

Страница 53: ...ut electric power monitor Display input electric power from inverter The monitor lamp kw V and A should illuminate while the contents of d014 is displayed Display 0 0 999 9 Display is in 0 1kw unit d0...

Страница 54: ...splay is in 10 times unit Trip monitor 1 6 This displays the details for the last six protective trips The trip monitor 1 displayed the details of the last trip Display contents 1 Trip Code Display an...

Страница 55: ...of Function Seite 55 180 The methods of trip monitor 1 Trip factor Note2 2 Trip frequency 3 Trip current 4 Trip voltage P N 5 Accumulated time on RUN 6 Power ON time 1 2 Note2 In case of no tripping i...

Страница 56: ...start frequency First Second highest frequency Unit Hz F001 A020 Second control setting of F001 A220 Third control setting of F001 A320 Operation direction This is effective when the operating command...

Страница 57: ...etting frequency with control terminals Terminals O L OI L O2 L 02 Setting frequency with digital operator F001 remote operator 03 Setting frequency with RS485 terminals for communication 04 Setting f...

Страница 58: ...ation command selection A002 05 Start Stop with option board 2 00 a contact NO Input FW a b NO NC selection C019 C011 C018 01 b contact NC Selection on stop When stop is commanded from the digital ope...

Страница 59: ...rol terminals are selected for the operation command you can still set whether the stop key of operator digital operator etc is effective or not Function code Data Contents 00 The stop key is effectiv...

Страница 60: ...0 2 F302 0 01 3600 Unit second Setting acceleration time from zero to maximum frequency Deceleration time F003 F20 3 F303 0 01 3600 Unit second Setting deceleration time from maximum frequency to zero...

Страница 61: ...n time ts ts Deceleration time tB tB JL JM x NM 9 55 x TS TL JL JM x NM 9 55 x TB TL JL J of the load converted into motor shaft kgem2 JM J of the motor kgem2 NM Motor revolving r min TS The maximum m...

Страница 62: ...his nominal value or there is risk of damage to the motor When changing second base frequency A203 third base frequency A303 an intelligent input terminal must be set to 08 SET 17 SET3 and switched on...

Страница 63: ...imit of setting Contents A004 A204 A304 30 400 Unit Hz Carrier frequency The carrier frequency of the PWM wave form output from the inverter is adjustable by changing b083 If the carrier frequency is...

Страница 64: ...tion of Function Seite 64 180 3 7kW 15 100 15 100 5 5kW 15 100 15 100 7 5kW 15 100 15 100 11kW 15 100 15 100 15kW 12 95 below 60 8A 15 100 18 5kW 8 80 below 60 8A 15 100 22kW 5 65 below 61 8A 6 80 bel...

Страница 65: ...mbining A005 A006 with the intelligent output at terminal In the case that reverse and FW forward terminals are ON the inverter operates reversely when main frequency command auxiliarly frequency comm...

Страница 66: ...0 100 Unit Set start rate for output frequency command 0 10V 4 20mA O OI end rate A014 A104 0 100 Unit Set end rate for output frequency command 0 10V 4 20mA 00 External start frequency Output freque...

Страница 67: ...O2 start rate A113 100 100 Unit Set starting rate for output frequency command 10 10V Notes O2 end rate A114 100 100 Unit Set ending rate for output frequency command 10 10V Notes Example 3 Notes The...

Страница 68: ...onse will be slower by setting a larger value The limit of setting is about 10ms 60ms set value 1 30 Function code Limit to set Contents A016 1 30 Can set with the 1 unit Output voltage gain Regarding...

Страница 69: ...frequency Output voltage outputs proportionally from 0 to the base frequency but the output voltage from the base frequency to the maximum frequency is constant regardless of frequency 2 Reduced torq...

Страница 70: ...If the base frequency is 60Hz the limit from 0 to 6Hz is constant characteristic Period The limit from 10 of base frequency to base frequency is reduced torque characteristic The voltage is output in...

Страница 71: ...0 Free V f frequency6 b110 0 Free V f frequency7 Free V f frequency5 b108 0 Free V f frequency6 Free V f frequency4 b106 0 Free V f frequency5 Free V f frequency3 b104 0 Free V f frequency4 Free V f f...

Страница 72: ...A242 A342 and A043 A243 A343 is outputted A042 A242 A342 sets a percentage level where the base frequency voltage is 100 The level set is the value of torque boost output voltage at 0 Hz When using th...

Страница 73: ...automatically by the condition of the load When using automatic torque boost it is important that the following two parameters are set correctly Set item Function code Setting limit Contents Motor cap...

Страница 74: ...DC braking time A055 0 0 60 0 Unit second The DC braking is stopped after this time delay has elapsed The time is tarted when the late time has elapsed 00 Edge movement Example 1 6 a DC braking edge...

Страница 75: ...the late time passes DC braking is started Please set DC braking time A055 or DC braking time by DB terminal paying attention to the heat of the motor Please set each setting in accordance with the s...

Страница 76: ...ter finishing the set time in A053 DC braking is started Set the frequency at which the DC braking will operate at with A052 The operation of Edge Level selection when using inside DC braking is diffe...

Страница 77: ...en stopping Example 6 a iii When stopping Example 6 b ii When stopping Example 5 a ii When stopping Example 5 b FW Output frequency A053 Free running A055 A052 FW Output frequency A053 Free running A0...

Страница 78: ...ting limit Contents Frequency max limiter A061 A261 0 00 frequency min limiter max limiter frequency Unit Hz Setting max of output frequency Frequency min limiter A062 A262 0 00 starting frequency max...

Страница 79: ...pplies to both forward and reverse directions a When operation command is control terminal Terminal A002 01 Terminal Revolution when O2 is 0V FW ON A062 on forward side REV ON A062 on reverse side b W...

Страница 80: ...quency band to jump Note Note The frequency to jump is fj 2 Hz Acceleration stop function When the inertial moment of a load is high this is the function to wait until the slip of the motor on startin...

Страница 81: ...s selected with A076 Or when the control terminal 01 is set with A001 the setting of AT selection A005 is invalid The contents changes when O2 is selected with A006 2 Basic operation of PID control 3...

Страница 82: ...It is possible to establish the maximum deviation level C044 on PID control When the PID deviation amount reaches the set level C044 it is possible to set an intelligent output C044 can be set from 0...

Страница 83: ...c changing by optional frequency In case of changing by intelligent input terminal assign 09 2CH to an Intelligent input terminal Set item Function code Data Contents Acceleration time 2 A092 A292 A39...

Страница 84: ...94 A294 is 01 Example2 Example1 In to set A094 A294 to 00 case Example2 In to set A094 A294 to 01 case Output 2CH FW Acceleration2 Deceleration2 Acceleration1 Deceleration1 F002 F202 F302 F003 F203 F3...

Страница 85: ...of both acceleration deceleration 2 The curve constant the swelling degree It makes the rough sketch reference and please decide the swelling degeree Time Output frequency Output frequency Time Time O...

Страница 86: ...lection b001 03 Start f equaling and stop decelerating on retry After stop start trip example1 Allowable under voltage power failure time b002 0 3 1 0 Units second If the instantaneous power failure t...

Страница 87: ...it for t2 seconds according to t0 t1 T0 T2 T1 Free run Power supply Inverter output Revolving time of motor example1 T0 T1 Trip according to t0 t1 Free run Power supply Inverter output Revolving time...

Страница 88: ...e to an intelligent output terminal 11 15 C021 C025 or alarm relay output terminal C026 Open phase protection function selection This is the function to warn when the inverter input supply opens Funct...

Страница 89: ...of the following states 1 Ripple current of main capacitor increases life of main capacitor shortens remarkably 2 In case of load there is danger that the capacitors or thyristors inside the inverter...

Страница 90: ...Reduced torque charcteristic To add to the time limit characteristic set with the reduced time rate b012 b212 b312 by each frequency b Constant torque characteristic Set this in to use constant torque...

Страница 91: ...Explanation of Function Seite 91 180 Reduced rated ratio Inverter output Frequency X1 0 0 60 X0 9 X0 8 5 2 5...

Страница 92: ...9 Don t operate Units A 3 Thermal warning A warning signal is outputted before overheat protection by the electronic thermal protection occurs Warning level is set with C061 Assign 13 THM to an intell...

Страница 93: ...his function When this function operates in the midst of accelerating the frequency will not reach the goal frequency the Inverter will adjust in the following way Make acceleration time longer Raise...

Страница 94: ...are possible output Set item Function code Data Description 00 On acceleration constant speed this is valid Overload advance notice signal output mode selection C040 01 On constant speed only this is...

Страница 95: ...0 10 to 9 99 Units Hz Reduced voltage start selection This function is to raise the voltage slowly on motor starting The lower this value the more torque is available on starting However by making th...

Страница 96: ...g run valid BRD operates During stop invalid BRD doesn t operate Selection of BRD b095 02 During run stop valid BRD operates Note 330 380 Units V In case of 200V class inverter setting is valid BRD ON...

Страница 97: ...tor Data 09 2CH Two stage adjustable speed Two stage adjustable speed function 11 FRS Free run stop Free run stop 12 EXT External trip External trip 13 USP Unattended start protection Unattended start...

Страница 98: ...ching P PI switching function 44 BOK Brake confirmation Brake control function 45 ORT Orientation Option function 46 LAC LAD cancel LAD cancel function 47 PCLR Position deviation clear 48 STAT Pulse t...

Страница 99: ...frequency Units Hz 1 Binary operation It is possible to set multi speed 0 to 15 by selecting 02 to 05 CF1 to CF4 on the intelligent input terminals Set frequency setting for speed 1 to 15 with A021 A0...

Страница 100: ...SF4 SF3 SF2 SF1 0 speed OFF OFF OFF OFF OFF OFF OFF 1 speed ON 2 speed ON OFF 3 speed ON OFF OFF 4 speed ON OFF OFF OFF 5 speed ON OFF OFF OFF OFF 6 speed ON OFF OFF OFF OFF OFF 7 speed ON OFF OFF OFF...

Страница 101: ...Valid Invalid 00 Free run on jogging stop 01 Decelerating stop on jogging stop 02 Direct braking on jogging stop Invalid example1 notes 03 Free run on jogging stop example2 04 Decelerating stop on jog...

Страница 102: ...4 A344 1st 2nd 3rd control system A061 A261 1st 2nd frequency upper limiter A062 A262 1st 2nd frequency lower limiter A092 A292 A392 1st 2nd 3rd acceleration time 2 A093 A293 A393 1st 2nd 3rd decelera...

Страница 103: ...tion gain H052 H252 1st 2nd P proportion gain H060 H260 1st 2nd Zero SLV limitter Display during setting isn t differentiated between the 1st control function or the 2nd 3rd control function So confir...

Страница 104: ...y by on off of an intelligent terminal when operation command is selected other than the operator Becoming the operation from the operation command that was selected by A002 if the signal is off and b...

Страница 105: ...or matching frequency start as output methods with the free run stop selection b088 Example 1 2 When you set the frequency setting to match b007 and the frequency detected is under this setting when t...

Страница 106: ...art is used and the motor speed is still high there is the possibility of over current trips After FRS terminal is switched OFF the Inverter reads the frequency of the motor and when it reaches the va...

Страница 107: ...M and when the CS terminal is switched OFF the retry wait time b003 is started Once the wait time has elapsed the inverter will then start and match the frequency which is set b007 When the Earth Leak...

Страница 108: ...he RS terminal is in the ON state for more than 4 seconds a communication error is caused Set item Functio n code Data Description Retry waiting time b003 0 3 100 Units seconds Reference to items of i...

Страница 109: ...N signal is still ON then the inverter will restart automatically Example2 Assign 13 USP to an intelligent input terminal Unattended start protection is shown as follows Example3 When 01 frequency mat...

Страница 110: ...rminal change with SET SET3 terminal It is possible for the Inverter to retain the frequency setting value from the UP DWN terminals Parameter C101 switches the memory On or OFF It is also possible to...

Страница 111: ...input function This function is used when a momentary push start stop control is required Set the operation command selection A002 to control terminal 01 Assign all of 20 STA 21 STP and 22 F R to thr...

Страница 112: ...in in case of signal OFF Setting item Function code Setting range contents Control method selection A044 A244 A3 44 03 04 05 SLV A344 is not 0 Hz domain SLV A344 is not V2 A344 Intelligent input selec...

Страница 113: ...tion C001 C008 43 PPI P PI switching Speed response H005 H205 0 01 99 99 Unit no demension PI proportion gain H050 H250 1 0 999 9 1000 Unit PI integration gian H051 H251 1 0 999 9 1000 Unit P proporti...

Страница 114: ...function 06 FA3 Arrival signal for only setting frequency Frequency arrival signal 07 OTQ Over Torque Over torque 08 IP Instantaneous stop signal 09 UV Under voltage signal Instantaneous stop under vo...

Страница 115: ...00 A contact NO Intelligent output 11 15 A b NO NC selection C031 C035 01 B contact NC 00 A contact NO Alarm relay output A b NO NC selection C036 01 B contact NC a contact Close with ON open with OFF...

Страница 116: ...t terminal C036 Set value Power source State of inverter AL1 AL 0 AL2 AL 0 On abnormal Close Open On On normal Open Close 00 a contact Off Open Close On abnormal Open Close On On normal Close Open 01...

Страница 117: ...esis frequency arrival signal is the following When ON ON with 1 of setting frequency maximum frequency Hz When OFF OFF with 2 of setting frequency maximum frequency Hz However in to set 06 FA3 25 FA5...

Страница 118: ...output relay is switched 3 Output setting frequency 06 FA3 25 FA5 The signal is switched only when the output frequency matches the arrival frequency set in C042 C043 FA3 C045 C046 FA5 on adjustable s...

Страница 119: ...cts that the output of the rotation speed of a motor or the output of LAD fell off from the zero speed detection level and be the function that outputs it By selecting a speed deviation excessive sign...

Страница 120: ...e function that inverter outputs trip factor as signal When 01 3bit or 02 4bit is selected in alarm code selection intelligent output terminal 11 13 or 11 14 compulsorily is outputted in alarm code Al...

Страница 121: ...Explanation of Function Seite 121 180 Setting item Function code Setting range contents Alarm code selection C062 00 01 02 Invalid 3bit code 4bit code...

Страница 122: ...t frequency example 2 0 Max frequency Hz 04 Output voltage example 1 0 100 05 Input electric power example 1 0 200 06 Thermal load ratio example 1 0 100 C027 07 LAD frequency example 1 0 Max frequency...

Страница 123: ...ode Data Description AM adjustment b080 0 255 After offset adjustment with C086 adjust according to memory AM offset Adjustment C086 0 0 10 0 Units V AMI adjustment C087 0 250 After offset adjustment...

Страница 124: ...Function Seite 124 180 Thermistor error level b099 0 9999 Units OHM Set the resistance value of temperature for trip according to thermistor methods Thermistor adjustment C085 0 0 1000 Use this as ga...

Страница 125: ...pan 01 Initializing setting for Europe Initial data Selection b085 02 Initializing setting for America Initialization methods After setting the above parameters initialize as follows b084 initializati...

Страница 126: ...14 C081 C085 C121 C123 O OI O2 terminal function 3 A002 01 03 04 05 b087 Stop key function A019 00 4 C001 C008 02 03 04 05 A028 A035 Multi speed function 5 A044 02 b100 B113 Control methods 6 A051 01...

Страница 127: ...Explanation of Function Seite 127 180 21 01 02 H020 H024 H220 H224 Motor constant 22 H002 H202 00 H030 H034 H230 H234 Motor constant Auto tunning...

Страница 128: ...equency b083 0 5 15 0 Units kHz Lower this when hunting occurs Stabilized factor H006 H206 H 306 0 255 Raise or lower when hunting occurs Operation selection on option error When an add in option is t...

Страница 129: ...celeration time The acceleration and deceleration time varies with the magnitude of the load or inertia 2 When the inertia of machine is more than about 20 times of that of the motor shaft a trip may...

Страница 130: ...ed to 4 4 After braking confirmation signal is inputted after braking releasing signal is outputted when BOK is not selected the inverter waits for the time for acceleration and then begins to acceler...

Страница 131: ...releasing current after arriving at releasing frequency b122 Set the mecanical late time to release braking from releasing signal outputting b123 Set the mecanical late time to stop braking from relea...

Страница 132: ...eous power failure invalid 01 Non stop function at instantaneous power failure valid Starting voltage of non stop function at instantaneous power failure b051 0 0 999 9 V Non stop at instantaneous pow...

Страница 133: ...general purpuse motor data Autotuning data Autotuning data offline autotuning valid 1st 2nd motor cpacity Selection H003 H203 0 2 55 0 Unit kW 1st 2nd motor pole Selection H004 H204 2 4 6 8 Unit Pole...

Страница 134: ...uning the motor used in the second inverter function is executed turn the second inverter terminal SET On 3 Turn the Run command On After turning the Run command on the motor automatically runs in the...

Страница 135: ...H222 0 00 655 35 Unit mH First second motor constant Io H023 H223 0 00 655 35 Unit First second motor constant J H024 H224 1 0 1000 Unit kgm2 First second autotuning motor constant R1 H030 H230 0 000...

Страница 136: ...totuning 2 Be sure to execute autotuning once when WATT general purpose motor as the data for online autotuning is computed during offline autotuning 3 After the motor stops online autotuning runs for...

Страница 137: ...motor constant Caution If the inverter operates less than twice capacity for the maximum adopted motor the full performances may not be demonstrated If satisfactory performance can not be obtained ple...

Страница 138: ...of the motor 2 If this inverter operates less than twice capacity for the maximum adopted motor the full performance may not be demonstrated 3 If satisfactory characteristics can not be obtained duri...

Страница 139: ...ol terminal is unstable Torque monitor value of this function displays 100 output torque when the motor rotates at synchronized revolution in the rated frequency equivalent to the rated output of the...

Страница 140: ...digital operator setting Selected torque limit range is valid in every driving condition 3 Analog input mode This mode sets torque limit value by voltage given to 02 terminal of control terminal 0 10...

Страница 141: ...Intelligent input selection C001 C008 40 41 42 Torque control valid invalid Torque limit switching 1 Torque limit switching 2 Intelligent output selection C021 C025 10 During torque limit TORQUE LADST...

Страница 142: ...mit 4 b044 0 200 Unit forward regenerating in4 zone individual setting Torque LADSTOP selection b045 00 01 Valid Invalid Intelligent input selection C001 C008 40 41 42 Torque control valid invalid Tor...

Страница 143: ...ol terminal is unstable Torque monitor value of this function displays 100 output torque when the motor rotates at synchronized revolution in the rated frequency equivalent to the rated output of the...

Страница 144: ...que limit value is valid in every driving condition When torque control valid invalid function is set to intelligent input terminal torque limit function is valid only during the signal turning ON Dur...

Страница 145: ...not 0 HZ domain A344is not V2 A344 is not Torque limit selection b040 00 01 02 4 zone individual setting Terminal changing Analog input Torque limit 1 b041 0 200 Unit forward driving in 4 zone indivi...

Страница 146: ...Transmission from lower bit Communication interface RS485 Data bit 7 8 bit Selection with Operator Parity No parity even odd Selection with Operator Stop bit 1 2 bit Selection with Operator Start meth...

Страница 147: ...ation Set item Function code Set value Description 02 Operator 03 RS485 04 Option 1 Data command C070 05 Option 2 02 Loop back test 03 2400 bps 04 4800 bps 05 9600 bps Communicating transmission speed...

Страница 148: ...are shown below Command list Comman d Command description Advisabili ty of all code Notes 00 Forward backward stop command 01 Setting of frequency command 02 Setting of intelligent terminal state 03 C...

Страница 149: ...R 02 30 31 30 30 31 33 30 0D Reply frame On normal reply 4 i Reference On abnormal reply 4 ii Reference ii 01 command This is to set frequency command Transmission frame Frame format Explanation Data...

Страница 150: ...anation of Function Seite 150 180 Note the data is 100 times as big as set value Example 5 Hz 500 000500 30 30 30 35 30 30 Reply frame On normal reply 4 i Reference On abnormal reply 4 ii Reference AS...

Страница 151: ...d command 000000000100000 0 PIDC PID integral reset 000000000000000 2 RV reverse command 000000000200000 0 000000000000000 4 CF1 multi speed1 binary operation 000000000400000 0 000000000000000 8 CF2 m...

Страница 152: ...planation Data size Value STX Control code Start of TeXt 1 byte STX 0x02 Code Station number of inverter 2 byte 01 32 Comman d Transmission command 2 byte 03 BCC Block check code 2 byte Exclusive OR o...

Страница 153: ...I code Output current A x10 8 byte Tenth ASCII code Revolution direction 8 byte 0 stop 1 forward 2 backward PID feedback monitor x100 8 byte Tenth ASCII code Intelligent input monitor 8 byte 5 referen...

Страница 154: ...ndicate status contents of inverter is constructed from the following three factors A B C Data Inverter status A Inverter status C Inverter status B Code Status 00 Initial status 01 Vdc on waiting set...

Страница 155: ...iage Return 1 byte CR 0x0D STX Code Data BCC CR Explanation Data size Value STX Control code Start of TeXt 1 byte STX 0x02 Code Station number of inverter 2 byte 01 32 Data Each monitor data on trip 4...

Страница 156: ...tion Data size Value STX Control code Start of TeXt 1 byte STX 0x02 Code Station number of inverter 2 byte 01 32 ACK Control code Acknowledge 1 byte ACK 0x06 Data Data tenth ASCII code 8 byte Note10 B...

Страница 157: ...arameter number of data 4 byte Note9 Data Data of parameter Tenth ASCII code 8 byte Note10 BCC Block check code 2 byte Exclusive OR of Code Command and Data 5 Reference CR Control code Carriage Return...

Страница 158: ...mmand This checks whether it is possible to store set value to EEPROM or not Transmission frame Frame format Explanation Data size Value STX Control code Start of TeXt 1 byte STX 0x02 Code Station num...

Страница 159: ...byte CR 0x0D Replay frame On normal reply 4 i Reference On abnormal reply 4 ii Reference xii 0B command This recalculates the internal motor constants This function is required when the motor capacit...

Страница 160: ...Exclusive OR of Code Command and Data 5 Reference CR Control code Carriage Return 1 byte CR 0x0D ii 01Inverter reply Reply frame Frame format STX Code ACK BCC CR STX Code NAK Error code BCC CR Explan...

Страница 161: ...code communication Error code Contents 01H Parity error 02H Sum check error 03H Framing error 04H Overrun error 05H Protocol error 06H ASCII code error 07H Reception buffer overrun error 08H Receptio...

Страница 162: ...n the case of the above transmission frame BCC calculates it as follows 3 0 3 1 3 0 3 1 3 0 3 0 3 0 3 5 3 0 3 0 Appendix ASCII code transformation table STX Code Command Data BCC CR 0x 02 0 1 0 1 0x 3...

Страница 163: ...check 2 Please set up the following with the operator of the inverter Please set up C071 Communication transmission speed selection to 02 Loop Back Test 3 Shut the power supply of the inverter at fir...

Страница 164: ...aken action causes an error to the inbuilt CPU the inverter output is switched off CPU1 External trip When a signal is given to the EXT intelligent input terminal the inverter output is switched off o...

Страница 165: ...ble BRAKE Option 1 error 0 9 These indicate the error of option 1 You can realize the details each instruction manual OP1 0 9 Option 2 error 0 9 These indicate the error of option 2 You can realize th...

Страница 166: ...ime that the inverter has been running hr 6 Accumulated time that the inverter has been powered up hr Display trip factor Please refer to 4 4 1 Display the state of inverter on tripping During reset D...

Страница 167: ...y A038 Starting frequency b082 085 285 Output frequency F001 Multi stage speed 0 A020 A220 086 Multi stage speed 1 15 A021 A035 Jump frequency 1 2 3 Jump width A063 A064 A065 A066 A067 A068 note 1 091...

Страница 168: ...5 b017 Free electronic thermal frequency 3 b019 Warning is cleared when the setting fulfils the above condition Data will be changed automatically to the basic code Note 1 The jump frequency will be a...

Страница 169: ...that the inverter is not dirty when operating Wipe clean with a soft cloth and synthetic detergent or ethanol Notes Don t use solvents containing any of the following acetone benzene toluene alcohol...

Страница 170: ...tricity 1 2 By watching 3 Measure with capacity measure 1 2 No abnormality 3 Over 80 of rated capacity Capacity meter Relay 1 Is there abnormal sound in operation 2 Is there damage to the contacts 1 B...

Страница 171: ...emoved Short terminals of R S T PD P N RB U V and W After the Megger test is complete reconnect the J61 connector as before 5 4 Withstand Voltage test Never perform a withstand voltage test on the inv...

Страница 172: ...indicated on no conducting With the effect of the smoothing capacitor the inverter conducts instantly and an infinite value isn t indicated Ohm number 10 ohms is indicated on conducting The values in...

Страница 173: ...Explanation of Function Seite 173 180 RB N No conduct N RB No conduct...

Страница 174: ...s installed in a cabinet ambient temperature is the temperature of the internal air of the cabinet Note2 DC bus capacitors are recommended to be replaced every 5 years And if the inverter is used in a...

Страница 175: ...D circuit built in Regenerative unit is required Stat ing Option inclusion resistance ED 3 1 9 1 1 0 85 0 6 0 4 2 400V class Inverter Model V30 00 015 HF V30 00 022 HF V30 00 037 HF V30 00 055 HF V30...

Страница 176: ...requency can be set Operato r Setting by key Volume DC 0 to 5V 5 to 5V 0 to 10V 10 to 10V input impedance 10k ohm 4 20mA input impedance 100 ohm Fr eq u e nc y Extend Signal Setting with RS485 communi...

Страница 177: ...ternal start end frequency rate Analog input selection Trip retry Reduced voltage start Overload restriction energy saving operation Restarting after an instantaneous power failure Various kinds signa...

Страница 178: ...Specification Seite 178 180 6 2 Dimension V3000 015 055NF HF V3000 075 011NF HF 15 2 25 24 6 13 14 14 69 2 26 24 18 7 20 17 89 7...

Страница 179: ...Specification Seite 179 180 V3000 150 220NF HF V3000 300NF HF 2 31 26 54 51 10 19 25 22 2 39 37 7 22 9 24 19 92...

Страница 180: ...Specification Seite 180 180 V3000 370 450NF HF V3000 550NF HF 25 55 52 10 39 30 2 25 70 67 12 48 38 2...