53
|
90
Safety Introduction Product Overview
1.
Loop the excess cable by bringing 2 sides of the loop together to flatten it
(
).
Figure 41
2.
Use a cable tie to secure the excess cable into a flat loop (
).
3. Use cable ties to secure the cable to the apparatus.
Note:
Do not secure the wire harness to hot or moving parts.
Note:
Waterous for information about obtaining a cable extension.
4. Install the cover. Refer to:
"Installing the Cover" on page 59
Installing the Master Waterway Check Valve
Note:
Refer to
"Overview Diagram—Typical" on page 20
for the
instructions in this section.
1
2
2. Outlet
3. Inlet
Figure 42
1. Use the victaulic or FNPT connections to install the waterway check valve
in-line with the waterway.
2. Install the inlet side of the waterway check valve towards the water pump.
Installing the Foam Manifold
Note:
Refer to
"Overview Diagram—Typical" on page 20
for the
instructions in this section.
2
1
1. Outlet
2. Inlet
Figure 43
1.
Ensure that the manifold is oriented with the flowmeter towards the top
.