8
|
90
Standard Components
This table shows the standard components that are associated with the different AQUIS foam system configurations.
Foam Only or Traditional CAFSystems
™
ONE STEP
™
and Eclipse GEN 2.0
™
Included
with
Kit L1210
AQUIS 1.5
AQUIS 3.0
AQUIS 6.0
AQUIS 1.5
AQUIS 3.0
AQUIS 6.0
Concentrate Wye Strainer
3/4 inch
3/4 inch
1 inch
3/4 inch
3/4 inch
1 inch
X
Concentrate Injection Check Valve
3/8 inch
3/8 inch
3/8 inch
3/8 inch
3/8 inch
3/8 inch
X
Cables
OIT/HMI (8-pin)
6 Meter
6 Meter
6 Meter
6 Meter
6 Meter
6 Meter
X
Flowmeter (4-pin)
3 Meter
3 Meter
3 Meter
3 Meter
3 Meter
3 Meter
X
Tank Level Switch (2 wire)
4 Meter
4 Meter
4 Meter
4 Meter
4 Meter
4 Meter
X
Foam Tee
or
Manifold
Tee with Flowmeter
Standard
Standard
Standard
Not Available
Not Available
Not Available
—
Master Waterway
Check Valve
(Includes a concentrate
injection port)
Upgrade
Upgrade
Upgrade
Not Available
Not Available
Not Available
Manifold
(Includes waterway
check valve, flowmeter and
concentrate injection port)
Upgrade
Upgrade
Upgrade
Standard
Standard
Standard
Operator
Interface
Terminal
(OIT)
Manual
Standard
Not Available
Not Available
Not Used
(See Note 1)
X
Digital
Upgrade
Standard
Standard
Operation
Instruction
Panel Plate
Manual OIT
No
(See Note 2)
Not Available
Not Available
Not Used
(See Note 1)
X
Digital OIT
Yes
Yes
Yes
1. For ONE STEP and Eclipse GEN 2.0 CAFSystems, the OIT port on the controller is connected to the system PLC which connects to the Tellurus™ HMI
panel.
2. Manual OIT plate includes operation instructions.