Operating and Disabling Manual Mode
In manual mode you can start or stop the pump and increase or
decrease the foam percent.
1. Press the
(FOAM button) to pause the foam system.
2. Press the
(up and down buttons) to adjust the
amount of concentrate that is injected into the waterway.
• Press the
(up button) to increase the value by 0.5.
• Press the
(down button) to decrease the value by 0.5.
3. Press the
(FOAM button) to start the pump.
4. Press the
(up and down buttons) simultaneously to
stop the pump and exit manual mode.
Auto Run Mode—If Equipped
The foam system activates automatically when auto run mode is enabled and
water is flowing. This eliminates the need to press the
(FOAM button) to
activate the system.
Changing the Display Mode
1. Press the
(SELECT button) to scroll though the following modes:
WATER FLOW → PERCENT → TOTAL WATER → TOTAL FOAM
and
then back to WATER FLOW.
2. Press and hold the
(SELECT button) for 3 seconds to lock the
display to the current mode.
Displaying Default Mix Percent
1. Press the
(SELECT button) until the PERCENT LED illuminates.
2. Press the
(up and down buttons) simultaneously. The
value displayed is the default mix percent.
Zeroing the Total Water Value
1. Press the
(SELECT button) until the TOTAL WATER LED
illuminates.
2. Press the
(up and down buttons) simultaneously. The
TOTAL WATER value is set to 0.
Zeroing the Total Foam Value
1. Press the
(SELECT button) until the total foam LED illuminates.
2. Press the
(up and down buttons) simultaneously. The
TOTAL FOAM value is set to 0.
Displaying the Supply Tank
Supply tank A LED is illuminated by default. Supply B tank LED is reserved for
applications that include a B supply tank with a dual tank selector kit installed.
The
(supply tank LED) indicates tank that is supplying the
concentrate.