Cleaning the Wye Fitting with Strainer
Clean the wye fitting every 50 hours of use.
1.
Close the shutoff valve at the supply tank.
2. Understand and follow the safety instructions from the foam concentrate
manufacturer.
3. Place a container underneath the strainer to collect the concentrate that
drains from the strainer.
4.
Remove the cap at the end of the wye fitting (
1
2
3
1.
Wye fitting
2. Strainer
3. Cap
Figure 61
5.
Remove the strainer from the wye fitting.
6. Flush the debris from the stainer.
7.
Insert the strainer into the wye fitting.
8.
Secure the cap to the wye fitting (
9.
Open the shutoff valve at the supply.
Inspecting the Hoses and Fittings
Check the hoses and fittings every 50 hours of use.
•
Check the hoses for wear, deterioration, and leaks.
•
Check the fittings for deterioration and leaks.
Inspect the Mounting Hardware
Inspect the mounting hardware every 500 hours of use.
•
Make sure the mounting hardware is free from oxidation.
•
Make sure the mounting hardware secures the pump to the apparatus.
Tighten if necessary.