9.
Prime the Cold Circuit. Holding a container under the dispensing faucet, Select and hold the cold
water icon until it lights up. While the cold water icon is lit, select the central dispense button to
start filling the cold tank with water. After one minute, the machine will automatically un-select the
central dispense button. Repeat selection of the central dispense button until the cold tank has filled
and water is coming out of the faucet (this could take 2 to 4 minutes), press and hold the main
dispensing button until a continuous flow of water is obtained. Once a continuous flow is obtained,
release the dispensing button. Cold tanks are now full.
10.
Prime the Ambient Circuit. Holding a container under the dispensing faucet, Select and hold the
Ambient water icon until it lights up. While the Ambient water icon is lit, select the central dispense
button to start filling the Ambient line with water (this could take 10 – 20 seconds). Continue to
dispense 15-20 fluid ounces more of water through the ambient option.
11.
Turn on the Green Heater/ Compressor switch at the rear of the machine.
12.
The
Cube
will now begin to heat / chill the water. The hot water should be up to operating
temperature after 8 to 10 minutes and the old water will take between 60 to 90 minutes to chill.
13.
Taste test the water, if there is any hint of taste in the water, flush and additional 1 ½ gallons of hot
water, then 1 ½ gallons of cold water. Do another taste test and if necessary repeat the flush again.
14.
Verify that the UV Lamp operates as expected (no UV Lamp alarm will sound on the display).
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet rays.
Never look directly at an operating UV light. Always disconnect before removal.
15.
Move the
Waterlogic CUBE
into its final operating position. Be sure that a minimum of 2” clearance
is maintained around both the sides and the back of the unit. This is important to allow proper
airflow and heat exchange of refrigeration system.
16.
When the unit has reached its Hot Temp Set Point, the heater will cycle off. When the unit has
reached its Cold Temp Set Point Temperature, the compressor will cycle off.
17.
Once the unit is at the target temperature(s), sample the water to ensure water meets expectations
and additional rinsing or adjustment is not required.
18.
Check the unit for any leaks. External Leak Protection is always recommended.
CUBE
Operating, Installation, and Service Manual
Page 27 - Revision: 6-23-2015
Содержание WL Cube
Страница 11: ...CUBE FLOW DIAGRAM CUBE Operating Installation and Service Manual Page 11 Revision 6 23 2015...
Страница 16: ...PCB LED CODES CUBE Operating Installation and Service Manual Page 16 Revision 6 23 2015...
Страница 53: ...CUBE MAIN DRAWING AND PARTS LIST CUBE Operating Installation and Service Manual Page 53 Revision 6 23 2015...
Страница 56: ...CUBE PARTS DRAWING AND PARTS LIST CUBE Operating Installation and Service Manual Page 56 Revision 6 23 2015...