75
Trouble shooting
Error codes which may arise on the control panel display
Open door. Close door and try to restart the
machine.
Error code returns
No error code
Start service program and activate door lock
(code 23, press START). Check input voltage to
door lock, PCB connector X71 between termin-
als 1 and 2.
Voltage correct.
Voltage absent or wrong.
Unscrew the door lock. Door and door lock).
Check voltage at door lock between terminals
X71:1 and 2 as illustrated.
Voltage correct.
Voltage absent or wrong.
3390
1
4
Check
voltage
2316
Error code/symptoms
Fault-finding
Transient fault in door lock or
program PCB.
Faulty control output from
program control unit PCB.
Replace PCB.
Cause/Action
Faulty wiring between
program control unit PCB and
door lock. Check wiring and
change if necessary.
Faulty door lock. Replace
door lock.
X71
03E
The lock has not locked the
door within the set time.