81
Trouble shooting
17E
Door status switch open,
even though the door lock is
locked.
Turn the machine’s wall switch off and on again.
Start a program.
Error code returns
No error code
Set program control unit to service mode. The
door status switch and door lock switch will now
be indicated by the LEDs shown left. Follow this
procedure (the door can be locked using code
23 and one press of the START button):
Door
Status of LEDs should be
for door lock switch: for door status
switch
open
OFF
OFF
closed, not locked OFF
ON
closed and locked ON
ON
Door lock switch LED ONDoor status switch LED
when door not locked OFF when door closed
Unscrew the door lock. Remove connection to
door lock switch "C" on door lock as illustrated.
LED ON
LED goes out
Remove PCB connector X71 from program
control unit PCB.
LED ON
LED goes out
Error codes which may arise on the control panel display
1
X71
Error code/symptoms
Fault-finding
2316
3390
Transient fault. No action
required.
Follow the chart for error code
02E to identify fault.
Cause/Action
Door lock faulty. Replace
lock.
Fault in wiring between PCB
and door lock. Check wiring
and replace if necessary.
Fault in program control unit
PCB. Replace PCB.
LEDs
indicating:
Door lock
switch
Door
status
switch
Содержание EXSM 230 S
Страница 4: ......
Страница 6: ......
Страница 32: ...32 Mechanical and electrical design Control unit ...
Страница 93: ...93 Trouble shooting If machine vibrates excessively A Tighten mounting bolts Fig 101 101 2408 ...
Страница 94: ......
Страница 123: ......