86
Maintenance
Weekly
•
Remove hose from drain connection and
clean inside drain valve.
Every three months
•
Remove the cover plates of the machine and
check that the V-belt of the motor is
undamaged and correctly tensioned.
•
Check that all tubing, piping and connections
are free from leaks.
•
Wipe and clean the inside of the machine,
making sure that the control components are
protected from moisture and dirt during the
cleaning operation.
90
4934
Fig.
90
Содержание EXSM 230 S
Страница 4: ......
Страница 6: ......
Страница 32: ...32 Mechanical and electrical design Control unit ...
Страница 93: ...93 Trouble shooting If machine vibrates excessively A Tighten mounting bolts Fig 101 101 2408 ...