43
Mechanical and electrical design
Imbalance measurement
At the start of every extraction sequence the system monitors variations in
the motor torque while the drum is operating at distribution speed. If these
variations are too great, it indicates that the load is unevenly distributed in
the drum. At this point extraction is halted, the motor speed is reduced to
wash speed and a fresh attempt to begin extraction starts. This procedure
will be repeated up to three times per extraction. After the third time the
system will decide whether the imbalance is “great” or “small”.
•
If the imbalance is “great”, the extraction stage of the program will end
without extraction having taken place.
•
If the imbalance is “small”, extraction will take place, but at a reduced
speed.