16
Installation
Connection of external units
(optional equipment)
Electrical installation must be carried out
by an authorized personnel!
All optional equipment connected must be
EMC-approved to EN 50081-1 or EN 50082-
2.
Connector X149-1.
Connector for external START/STOP/PAUSE
function for machine.
Connector X148-1 (only on machines with at
least two I/O boards).
Connector for external buzzer or signal.
Connector X146-1.
Connector for external liquid supply pumps.
Control signals on 1-4 on left and Neutral to be
connected to 1 and Phase to 2 on right-hand
side.
Connector X147-1 (only on machines with at
least two I/O boards).
Connector for additional external liquid supply
pumps.
Connector X145-1 (only on machines with
three I/O boards).
Connections for recycling system 2.
Connector X144-1 (only on machines with at
least two I/O boards).
Connections for recycling system 1.
12
4940 B
Fig.
12
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
5 6 7 8 9
11 12
10
5 6 7 8 9
11 12
10
X147-1
X145-1
X144-1
471 75 96 01
1 2 3 4
1 2 3 4
1 2
1 2
1 2 3 4 1 2
1 2 3 4 1 2
1
1
X149-1
X148-1
X146-1
471 76 97 01