Maintenance
Maintenance
Preventive maintenance has been reduced to a
minimum by the careful design of reliable
components and material.
However, the following measures should be
taken at regular intervals and in proportion to the
hours of service.
Make certain that all electrical power to the
machine is shut off before removing top or
rear panels.
Daily
•
Check the door lock and interlock before
starting operations.
•
The soap supply box should be cleaned at the
end of each working day as follows:
-
Use a spatula to scrape loose any
detergent which may have stuck on the
inside of the dispenser.
-
Flush the loosened detergent with warm
water.
-
Wipe dry and leave lid open.
•
Check that the drain valve does not leak and
that it opens properly.
•
Check that the door does not leak. Clean
residual detergent and foreign matter from the
door gasket.
•
Wipe the outside of the machine.
•
When the machine is not in use, leave door
slightly open to allow moisture to evaporate.
89
4947
Fig.
89
Содержание EXSM 230 S
Страница 4: ......
Страница 6: ......
Страница 32: ...32 Mechanical and electrical design Control unit ...
Страница 93: ...93 Trouble shooting If machine vibrates excessively A Tighten mounting bolts Fig 101 101 2408 ...
Страница 94: ......
Страница 123: ......