Trouble shooting
Error codes which may arise on the control panel display
Error code/symptoms
Fault-finding
Cause/Action
Are there water in the drum?
Yes
No
Disconnect the level tube
from the program PCB.
Turn the machine’s wall
switch off and on again.
Start a program.
Error code 06E No error
code or
error code 01E
Turn the machine’s wall switch off. Does water
run out of the drum?
Yes
No
Turn on wall switch. Start a program and let it
run.
Still an error code.
No error code.
Check to see if the discharge valve is partially
blocked or not opening fully.
Discharge valve OK
Discharge valve not OK
06E
Water level signal above
parameter set, on program
start-up.
3350
Faulty control signal to
discharge valve from program
control unit PCB. Replace
PCB.
Connec-
tion
level
tube
Level tube probably blocked,
due to fluff of wrongly
mounted. Clean or replace
tube.
Nipple blocked on drain valve.
Check the discharge valve
(see Chapter 38). The service
program can be used (code
21) to open and close the
control valve for the discharge
valve.
Level sensing device on program
control unit PCB not working or
incorrectly calibrated.
Check zero level in the service
program see chapter 12 page 4,
code 24, zero level shall be
between 0 and 4.
Transient fault. No action
required.
Check to see if the discharge
valve is partially blocked or
not opening fully (see Chapter
38).