78
Trouble shooting
Error codes which may arise on the control panel display
10E
The water level is above the
safety level set for after drain.
Is water visible in the drum?
Yes
No
Remove the water drain
valve from the drum. Is
there water at the bottom
of the drum?
Yes
No
Disconnect the level tube
from the program PCB.
Turn the machine’s wall
switch off and on again.
Start a program.
Error code
No error
06E or
code or
error code
error code
10E
01E
Turn the machine’s wall switch off. Does water
run out of the drum?
Yes
No
Turn on wall switch. Start a program and let it
run.
Still an error code.
No error code.
Check to see if the drain valve is partially
blocked or not opening fully.
Drain valve OK
Drain valve not OK
3350
Error code/symptoms
Fault-finding
Level tube probably blocked.
Clean or replace tube.
Level sensing device on
program control unit PCB not
working or incorrectly
calibrated.
Transient fault. No action
required.
Faulty control signal to drain
valve from program control
unit PCB. Replace PCB.
Check the drain valve. The
service program can be used
(code 21) to open and close
the control valve for the drain
valve.
Cause/Action
Connection
level tube
Check to see if the drain
valve is partially blocked or
not opening fully.
Содержание EXSM 230 S
Страница 4: ......
Страница 6: ......
Страница 32: ...32 Mechanical and electrical design Control unit ...
Страница 93: ...93 Trouble shooting If machine vibrates excessively A Tighten mounting bolts Fig 101 101 2408 ...
Страница 94: ......
Страница 123: ......