45
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
The lack-of-product protection with level probe is not supplied with the 2K system and has
to be realized on-site.
6.4.6 VENTILATION OF THE SPRAY BOOTH
WARNING
Toxic and/or flammable vapor mixtures!
Risk of poisoning and burns.
Operate the device in a spray booth approved for the working materials.
-or-
Operate the device on an appropriate spraying wall with the ventilation (extraction)
switched on.
Observe national and local regulations for the exhaust air speed.
6.5
GROUNDING
WARNING
Fire, explosion and electric shock hazard
Danger to life by electric shock and explosion.
The device must be electrically connected to the equipotential bonding (ground);
the ground in the electrical system is not sufficient.
A qualified electrician must complete all grounding and wiring connections and check
the resistance.
Operation according to the safety regulations, fire protection and electrotechnical
rules.
Must be de-energized before work is commenced on active parts.
WARNING
Heavy paint mist if grounding is insufficient!
Danger of poisoning.
Insufficient paint application quality.
Ground all device components.
Ground the work pieces to be coated.
Make sure to include the control cabinet and the fluid cabinet in the local equipotential
bonding.
The 2K system, the pumps, all accessories and all parts that come into contact with the
sprayer have to be grounded non-Ex or Ex according to the following grounding scheme.