OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
16
Batch Mode
Allows a recurring and pre-defined flow rate to be discharged
(see software documentation).
Measuring unit for pot life
minutes or seconds. (Change recipes accordingly after
changeovers!)
Booster pump
(Off / A-side / Mix-side)
A valve selection at start
"On": After starting, a prompt appears asking which A
valve is to be used for the selected recipe.
Number of tanks
for filling level monitoring.
17
Pre-flushing after end flushing
"On" = After an end flushing, a pre-flushing must
be undertaken. Prerequisite: pre-flush recipe is defined and selected in the paint
recipes.
Pre-flushing after paint change flushing
"On" = A pre-flushing must be
undertaken after a recipe change flushing. Prerequisite: pre-flush recipe is defined
and selected in the paint recipes.
Flush interruption ok?
"On" = The flushing process can be interrupted and e.g.,
the new paint filled. "Off" = The entire flushing process must be undertaken first. If
flushing is aborted, the process starts again afresh.
Air flushing valve
(On/Off) "On" = Air flushing is fitted.
External mixer
(On/Off)
Flushing external mixer as standard
"On" = The FLUSHING push button starts
mixer flushing ("Mix") of the last paint recipe used. ( Flushing from external mixer)
"Off" = The FLUSHING push button starts end flushing ("End") of the last paint recipe
used.
18
Number of automatic product pressure regulators
(0 / 1 / number of guns). "1" =
Automatic product pressure regulator in front of splitter valve. "Number of guns" =
An automatic product pressure regulator is fitted for each gun.
Maximum product pressure
for automatic product pressure regulator.
Pressure regulator fully open during flushing
For manual product pressure regulators: "On" = During flushing, the product pressure
regulator is subjected to full air pressure.
For automatic product pressure regulators: No function.
Pulse time at flush for prod.press reg.
For manual product pressure regulators, if the above function is switched on:
pulse time for changes between working pressure and full air pressure.
For automatic product pressure regulators: pulse time for changing between
flushing pressure (specified in recipe) and 0 bar.
"0.0 sec"= no cycling.