Flow regulation
(On/Off).
P-
(proportional-)part and
I-
(integral-)part of controller.
Number of flow measurements
, which are included in the calculation.
Time period
between the flow measurements.
20
Flow meter in external flushing agent
(On/Off).
Flow switch in external flushing agent
(On/Off).
Flushing monitoring in seconds
(flushing with paint valves / flushing external mixer
/ gun flushing / dump flushing):
"no" = The flushing time runs, regardless of whether or not flushing agent flows.
"Gun monitoring" = The flushing time only runs when there is a gun signal.
Prerequisite: gun monitoring signal from flow monitor or robot,
not
from air
monitoring.
"Flow switch" = The flushing time only runs when there is a signal from the flow
switch. Prerequisite: "Flow switch in external flushing agent" is activated (see above).
21 * An
information signal
can be generated:
− As soon as the filling is complete (Setting "Filling complete: -> Information signal").
− As soon as the gun in the gun flush box must be changed (Setting "GFB gun change:
-> Information signal").
− During the flushing process (see Chapter
Duration of the alarm horn sounds according to "Information signal switch-on time"
and "Information signal break time". ("Number of cycles for information signal" =
How many information signal cycles should sound as soon as the filling is complete.)
22 *
Warning signal on alarm horn
(On/Off). Duration of sounds according to "Warning
signal switch-on time“ and "Warning signal break time".
23 **
Password level 2 / 3
Password input for password level 2 / 3.
Reset initialization
"OK" = When the system is switched on the next time, the
initialization program starts (e.g., for training purposes). The current settings are
preset, nothing is lost.
Start software update
"OK" = A software update is executed. Special knowledge
is required for this purpose (observe separate manual).