112
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
Example
Accesory "Set 1" requires a digital output. The Q12 output in the D2 module is still free and
"Set 1" is connected there. The D2:X2_14 connection is assigned to this output.
Call up the digital outputs: "Output" in the controller ("Menu" "I/O Config").
Then scroll to the "D2" module with the arrow keys . Assign there to the "Q12" output
the accessory function "Set 1" (according to the assembly manual).
Connect the accessory "Set 1" in the control cabinet to the D2:X2_14 terminal
(according to the assembly manual).
13.3 CONTROL CABINET DIAGRAMS
Pneumatic Diagram
A general pneumatic diagram can be found on the USB stick (Order No., see Chapter
The pneumatic diagram is also available at order no. 2364198.
Circuit diagram
A system specific circuit diagram can be found on the USB stick (Order No., see Chapter
).
A general circuit diagram is available under order no. 2359815. The 2-circuit circuit diagram
is available at order no. 2363147.
13.4 EXPANSION AND ACCESSORY SETS
Functional descriptions
The descriptions of the expansion and accessory sets can be found in the corresponding
assembly manuals on the USB stick (Order No., see Chapter
Assembly
Have expansion and accessory sets be installed only by specially trained staff or a
WAGNER service center.
Carry out each assembly according to the corresponding assembly manual.
A skilled person must check to ensure that the device is in a reliable state after it is
mounted.
Most accessory sets require conversions in the control cabinet.
WARNING
Electric shock hazard inside the control unit!
Danger to life from electric shock.
May only be installed/maintained by skilled electricians or under their supervision.
Operation according to the safety regulations, fire protection and electrotechnical
rules.
Must be de-energized before work is commenced on active parts.