103
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
A257
Data conflict
Different settings data on MPX / ADC and touch panel.
− Check stroke sensor settings in the touch panel and send again.
A258
MPX is not sending data
A259
MPX is not responding
Communication errors between the touch panel, MPX multiplexer and A/D converter ADC.
− Check cable with plug.
− Check compatibilities (software versions touch panel / MPX / ADC).
− If this occurs repeatedly, contact the WAGNER Service Department.
A260
Sending to MPX interrupted
The sending of settings data to the MPX and ADC was not terminated. Data must be sent
again. (See software documentation.)
A261
Data from wrong sensor
Communication errors between the touch panel, MPX multiplexer and A/D converter ADC.
− Check cable with plug.
− Check compatibilities (software versions touch panel / MPX / ADC).
− If this occurs repeatedly, contact the WAGNER Service Department.
CAN bus fault rectification
A500
Initialisation error
Internal error when starting up the touch panel.
− Switch off the system and back on via the main switch.
− Contact the Service Team.
A501
CAN master error
The touch panel CAN master process not possible.
− Switch off the system and back on via the main switch.
− Contact the Service Team.
A502
CAN master alone
The touch panel CAN master found no connected slaves on the CAN bus.
− Check the connected modules: voltage supply, CAN cable, address, baud rate and
terminating resistor. See spare parts catalog (Order No., see Chapter
).
− Switch off the system and back on via the main switch.
− Contact the Service Team.