117
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
13.4.3 ACCESSORIES SETS FOR EXTERNAL FLUSHING AGENT
External flushing agent can be used for:
− Mixing head cycle, flushable
− External mixer
− Splitter valve, flushable
− Dump valve, flushable
− Dump valve for waste separation
The external flushing can be done in three ways. Optionally, an accessory set is required
(installed by the WAGNER Service Department):
Flushing mode
Detail in the
flushing recipe Meaning
Accessories set
Ex
Non-Ex
Flushing over a
period of time
Flush. time
Flushing time runs,
if the flushing valves
are open.
--
--
Flushing with
flow monitor
Flush. time
Flushing time runs,
if flushing agent
flows.
Flow monitor lacquer, Ex,
Order No. 2359025
Flow monitor
lacquer, non-Ex,
Order No. 2359024
Cable, Order No. 9956160,
Length = distance from
control cabinet-flow
m 2m
Flushing with
flow meter**
Flushing Qty
Precise flushing
quantity is used.
Not orderable as a set
* With XL design: Flow monitor lacquer, Ex XL, Order No. 2360619
** Can not be used for 2-circuit systems.
13.5 REMOTE CONTROL (OPTION)
The remote control can be operated in the EX area, allowing the following functions to
be controlled: start; stop; flushing and recipe change. In addition, a signal display for the
current recipe and displays for the operating status (Filling, Ready and Alarm) can be
installed.
Designation
Order No.
Remote control
2341153
Magnetic pin, complete
2342917
Extension cable 15 m; 49 ft for remote control
2343063
Maximum extension of 2 times 15 m; 49 ft. (Total 45 m; 147 ft.)