62
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
7.11 ENTER PAINT RECIPE
B_05476
Menu
Menu
AB : C
A : B
D
of ABC
Go to next page
Save paint recipe.
(with password level 1 or higher)
Select existing paint recipe.
New recipe: see Chapter
Enter
mixing ratio (volume)
for the selected
recipe
0.1:1–50.00:1
0.02% – 1,000.00%
If one or several components are not required:
enter 0.00:1 or 0.00%.
1K application: Enter 0.00:1 or 0.00% for all
components except for one.
The flow is measured by volume and the mixing
ratio is entered and controlled volumetrically by
default.
Select
product valves
for available
components.
If one or several components are not required:
B valve = "---------"
1K application: Enter "---------" for all components
except for one.
Page 2
− Enter
pot life
.
− Select
flushing recipes
to be used:
Is carried out, ...
End
:
...
after
this paint recipe has been used when end flushing is being carried out.
R-R
:
...
after
this paint recipe has been used when the recipe is changed.
Mix
: * ... when flushing just from the external mixer to the gun.
Pre
: * ...
before
using this paint recipe.
(For whether a recipe change and / or end flushing comes first: see Chapter
, "Pre-flushing
after paint change flush" or "Pre-flushing after end flushing").
* May also be missing, depending on configuration.
Select empty field if no flushing recipe is to be active.
Page 3 (option)
−
Product pressure when filling and working.