Status:
Output volume level drops directly to volume level of 20 (including
offset.) If the volume level is less than 20, or if the unit is in Mute
mode, pressing the Fade button will not change the level.
19. User monitors input while recording (any input) (Front Panel only)
If the user wants to be able to listen to the recording as it is being made on such an
equipped tape deck then the monitor function is used. The selected input being
recorded will still be routed to the record output (which is connected to the input on
the tape deck), and the output from the tape deck connected to the tape input will
become the amplified signal.
User input:
User presses the Tape button while holding the Mon/Proc button.
Indication:
Tape LED and Mon/Proc LED are lit (red) while selected input
stays lit.
Status: Preamp
output
switches
from selected input to selected tape
monitor position, while keeping input selected. Volume control
continues to be able to be varied, either from front panel or remote
control.
20. User locks Front panel Programming Lockout (during power down cycle only)
(Front panel or RS-232 port) (Unlocked mode only)
Programming lockout is to lock all programming functions so that they are not able to
be accidentally re-set to some unintended setting during normal operation. (To make a
system change requiring re-programming, lockout is unlocked and then re-locked after
making the change.)
User input:
User presses front panel Power button while holding Mon/Proc
button down. Addressable through RS-232 port also – see specific
section for command structure.
Indication: No
indication.
Status:
Unit does not allow any programming modes (Triggers, or trigger
timing, Unity gain, input mode, input disable or enable, and input
offset) while locked
21. User Powers down to Stand-by mode (Front Panel, remote control)
If trigger functions are used to signal the remote power amplifiers to be turned on the
preamplifier should not be left powered up when not in use, and power down to
standby condition is required to await power on command.
User input:
User presses Power button, either on front panel or remote control
while the unit is in power-on mode, or sends a discrete power off
signal from external remote.
Indication:
The display turns to double dash. All other indicators are turned off.
TL5.5 SERIES II Preamplifier Owner’s Manual