ECU Converter HORNET Version: 1.1
Page 7/18
2.1.2.3
Alarms / Parameterization
From the STATUS DISPLAY 1, the parameter display can be accessed by pressing the
▼ button down.
With the ▲ Up button the parameter display will left (..to STATUS DISPLAY 1). Within the
parameter display you can scroll with the ►Right button - or - ◄Left button between the
parameter groups "Alarme", „Alarmcode", "MSB Adressen" and "ECU-EX-Name".
When the desired parameter group is selected, the parameter can be changed by using ▼Down
and ▲Up button.
Value changes are made with the
►
Right button – or-
◄L
eft button.
Example of parameter selection and parameterization:
▼Down button
►
Right button
▼Down button
►
Right button (multiple times)
▲Up button
▲Up button
Parameter
group
Parameter Value range
Step size
Set-Value
(Default)
Alarme
FUEL
10
. . . 2500 ml
10 ml
800 ml
BATT
3.0
. . . 12.0 V
0.1 V
4.0 V
RPM
20.000 . . . 99.900 rpm
100 rpm
20.000 rpm
Alarmcode
FUEL
A, B, C, . . . , X, Y, Z
C
BATT
U
RPM
V
MSB-
Adressen
PUMP
OFF, 0, 1, 2, 3, . . . ,13, 14, 15
2
FUEL
3
EGT
4
RPM
5
BATT
6
Status
7
THRO
8
F-FLOW
9
FUEL-%
10
Jeti-Sensor
EX Name
VSECU, L-ECU, R-ECU, 1LECU, 2RECU
VSECU
<
A l arm
>
FUEL 1150m l
1377mAh
A l arm
FUEL <
1150m l
>
1377mAh
A l arm
FUEL
<
800m l
>
1377mAh
<
A l arm
>
FUEL 800m l
1377mAh
<
A l armcode
>
FUEL C
1377mAh
536C 41 . 1/V35%
AUTO 3 . 1V P1 . 14
1377mAh