background image

 

ECU Converter HORNET Version: 1.1 

www.VSpeak-modell.de

 

Page 14/18 

2.3

 

Multiplex MLink (MSB) 

The MSB (Multiplex Sensor Bus) is only uni-directional. You can only see the telemetry data, 
but you cannot change parameters of the HORNET ECU. 

2.3.1

 

Adress-Assignment 

The VSpeak ECU Converter at delivery uses following addresses: 

 

 

address 

comment 

PUMP 

Pump Voltage in V 

FUEL 

Alarm 

Fuel Level in ml 

*) 

EGT 

Exhaust Gas Temperature in °C 

RPM  

Alarm 

Turbine RPM 

BATT  

Alarm 

Battery Voltage in V 

Status 

Turbine-Status (non on evo and royal) 

THRO 

Throttle Value in % 

*) 

F-FLOW 

Fuel Flow in ml 

*) 

FUEL in percent 

10 

Fuel Level in % 

*) 

*) FUEL, F-FLOW and Throttle not on HORNET 2 

A change of address assignment and setting of alarms for FUEL, RPM, and BATT can be  

done  with  the  Jeti  system,  for  example,  by 
using a Jetibox, (s. section 2.1.2.3) 
- or by using the HoTT system with a Smartbox 
(see section 2.2.4.). 

In section 2.0 the requisite change between the 
telemetry systems is described. 

 

 

 

 

2.3.2

 

Turbine-Status 

To display the turbine status there are various 
preset messages in the radio or in the external 
display.  These  do  not  match  the  normal 
ECU  messages  1:1,  so  the  closest  match  has 
been chosen. Please refer to the table on the left. 

For  HORNET  status  messages  without  a 
corresponding  MSB  message  (grey  fields  in 
the table) the last message is shown until a new 
message, which can be translated, is shown. 

 

 

 

 

AUTO 

RUN (reg.) 

AUTO-HC 

RUN … 

BURNER ON 

PreHeat1 

CAL IDLE 

LearnLO 

CALIBRATE 

LearnHI 

COOL-DOWN 

Cooling 

DEV.DELAY 

 

EMERGENCY 

 

FUELHEAT 

PreHeat2 

FUELIGNIT 

Ignite... 

GO IDLE 

Stabilise 

OFF 

-OFF- 

PROP IGNIT 

Ignite... 

RAMP DELAY 

AccelrDly 

RAMP-UP 

acceler. 

SLOW DOWN 

SlowDown 

STANDBY 

Stby/START 

STEADY 

acceler. 

WAIT ACC 

acceler. 

 

Содержание ECU converter HORNET

Страница 1: ...MINAL can be sent via telemetry to the radio To avoid unwanted electrical effects between the ECU and RC system the VSpeak ECU Converter is galvanically isolated via optocouplers The ECU Converter can...

Страница 2: ...raupner HoTT 9 2 2 1 Sensortype 9 2 2 2 Textdisplay 9 2 2 2 1 Special Characters 10 2 2 2 2 Key assignment 11 2 2 3 Data Display Speech 11 2 2 3 1 GAM General Air Modul 11 2 2 3 2 ESC Electronic Speed...

Страница 3: ...ar The provided LED socket can be mounted in the hull in order to see the LED from outside of the model 1 3 Connection The RJ12 Western plug has to be connected DIRECTLY to the TERMINAL socket on the...

Страница 4: ...r another telemetry system is possible here 2 0 Selection of the telemetry system When you turn on the Telemetry System is signaled by a LED for a period of 3 seconds While the blue LED flickers the S...

Страница 5: ...ed on HORNET II On HORNETT II PUMP and BATT values are only updated as long as these voltages are shown on STATUS DISPLAY 1 The EX data IS ONLY UPDATED if the HORNET ECU is on STATUS DISPLAY 1 after s...

Страница 6: ...he following table how these characters are translated battery full battery normal battery empty Glow plug defective Temperature sensor defective Pump running Pump voltage switch operation unit C unit...

Страница 7: ...are made with the Right button or Left button Example of parameter selection and parameterization Down button Right button Down button Right button multiple times Up button Up button Parameter group P...

Страница 8: ...s already associated with another value the current is set to OFF 2 1 2 4 Expandermenu If the VSpeak ECU Converter is connected to an Expander or Centralbox and the ECU Converter display is activated...

Страница 9: ...sor type In this mode it is possible to have speech output for the sensor values 2 2 1 Sensortype The VSpeak ECU Converter for HoTT is a GAM General Air Module or a ESC sensor Electronic Speed Control...

Страница 10: ...he following table how these characters are translated battery full battery normal battery empty Glow plug defective Temperature sensor defective Pump running Pump voltage switch operation unit C unit...

Страница 11: ...display you have a real temperature of 405 414 C The pump voltage is displayed as Cell Voltage 1 ranging from 0V up to 5 10V accuracy 20mV It is also displayed as Batt 2 bigger values than 5 1V possi...

Страница 12: ...the current ie 81 6A correspond to 81 6 tank level The tank level is thus easy to read via the associated bar display The 100 value is set at startup The value in ml transferred during the powerup of...

Страница 13: ...nal tone The rotation speed monitoring is activated by reaching the AUTO status and deactivates when the pump voltage reaches 0 00V A speed alarm can thus signal a turbine flameout 2 2 4 2 MSB Adresse...

Страница 14: ...one with the Jeti system for example by using a Jetibox s section 2 1 2 3 or by using the HoTT system with a Smartbox see section 2 2 4 In section 2 0 the requisite change between the telemetry system...

Страница 15: ...e value in ml transferred during the powerup of the ECU is used as 100 value for calculation So after powerup you get a consumption of 0 0A You can change the value displayed on Amps and JetCat by dou...

Страница 16: ...ere are some limitations There will be no values for fuel level fuel flow and throttle transmitted These values are set to 0 Thus no alarm can be generated for FUEL Battery and Pump Voltage are only r...

Страница 17: ...ries A micro SD card is NOT included in the package For updates only Micro SD cards with a maximum capacity of 2GB are supported You can obtain a matching card at www vspeak modell de Western cables c...

Страница 18: ...bles under fire conditions EN60950 Information technology equipment Safety EN61000 6 1 Electromagnetic compatibility EMC EN61000 6 3 EN55022 Information technology equipment Radio disturbance characte...

Отзывы: