36
4. Mount the sensor to the suspension and clamp in place for a minimum of 10 minutes
5. Connect the internal domain cable to the cable chain
• Ensure that cable to cable connections are well supported
• Avoid running cables on or near sharp objects
• Keep cables away from hot components such as exhausts and engines
Use cable protector to protect the cable at positions where it may be exposed to damage
• Use cable ties to secure any excess cable to the chassis of the vehicle
Ensure that you make a note of the serial number of the sensor and the location on the vehicle
where it is installed.
6. Make a note of the serial number of the sensor, the position it is located on the vehicle and the
direction it is facing e.g. SN: xxxx, position 1, front right axle, facing forward
• The internal domain
cable is attached to the
rear of the transducer.
The opposite face is
used to indicate which
direction the sensor is
facing
It is recommended that you use the system
configuration table to record this information. See
“System configuration table” on page 116
Cable attatched to the
rear of transducer
Front of the vehicle
Sensor Facing Forward
Front of the vehicle
Sensor Facing Backward
TruckWeigh
®
Содержание TruckWeigh
Страница 1: ...vpgonboard com TruckWeigh Installation Setup and Calibration Manual...
Страница 2: ...2 TruckWeigh...
Страница 8: ...8 TruckWeigh...
Страница 9: ...9 Installation TruckWeigh...
Страница 15: ...15 Tractor Suzi Trailer Suzi Rigid Suzi TruckWeigh...
Страница 41: ...41 Configuration TruckWeigh...
Страница 87: ...87 Calibration TruckWeigh...
Страница 98: ...98 TruckWeigh...
Страница 99: ...99 System options TruckWeigh...
Страница 114: ...114 TruckWeigh...
Страница 115: ...115 Appendix A TruckWeigh...
Страница 119: ...119 Appendix B TruckWeigh...
Страница 122: ...122 TruckWeigh...
Страница 123: ...123 Appendix C TruckWeigh...
Страница 126: ...126 TruckWeigh...
Страница 127: ...127 Appendix D TruckWeigh...