89
Maintenance. Drive
Checking oil level, power trim
Trim the drive in as far as possible. Check the oil level
is between the MAX and MIN markings on the oil con-
tainer. Top up if necessary using ATF oil. Cleanliness
is extremely important, no dirt must get into the drive
when topping up with oil.
If the system has been drained, fill with new oil and
trim the drive in and out 6–10 times to vent the system.
Check the oil level and top up if necessary.
Changing universal joint bellows
Check the condition of the joint bellows once a year.
It must be changed if there are any visible cracks or
other defects.
The joint bellows should be renewed every 200 ope-
rating hours. The drive must be dismantled from the
suspension fork in order to change the joint bellows.
Dismantling the drive requires knowledge and special
tools. Contact your Volvo Penta service centre.
Checking exhaust bellows
Check the condition of the exhaust bellows once a
year. It must be changed if there are any visible cracks
or other defects.
WARNING!
Never work on the drive bellows
or hydraulics without first securing the drive in
raised position in such a way that it cannot fall
down. The drive can cause severe personal injury
if it falls down.
Special tool no.885800, applied correctly, will prevent
the drive from falling down. Fit the tool as follows: Trim
out the drive to max and apply the special tool.
Then inspect the bellows thoroughly for damage and
change if necessary.
WARNING!
Do not overload the tool by standing
on the raised drive.