22
•
Critical Alarms: Alarms that force the unit to disrupt operation.
These alarms automatically reset when you press ENTER
while in the Idle screen. The unit resumes operation if the
triggering condition is no longer active, for example the
leakage alarm.
ALARMS
Name on
screen
Description
Resolves
Automatically
Alarm
Category
LOW
PURIFY
Low flow during the Purify step. Set in the Setpoints
screen. Only triggered at the end of the Purify phase.
Unit jumps to Idle, press ENTER to resume operation.
No
Critical
LOW
WASTE
Low flow during the Waste phase. Set in the Setpoints
screen. Only triggered at the end of the Waste phase.
Unit jumps to Idle, press ENTER to resume operation.
No
Critical
BYPASS
ALARM
Pure line pressure has dropped below the set point of
the starting signal pressure switch (2 bar / 28 psi) for
more than 1200 seconds. Alarm will resolve
automatically when pressure increases above 2 bar /
28 psi.
Yes
Important
CAB. TEMP
High temperature within the electrical cabinet. Unit
jumps to HT-Wait until it cools down then resumes
normal operation.
Yes
Important
LEAKAGE
If the two leakage sensors come into contact with
water, this alarm will be triggered, and the system will
go to Idle.
No
Critical
CIP L.
LEVEL
CIP solution tank is almost empty.
NOTE:
CIP solution level is calculated based on the
CIP’s pump capacity to exhaust the 1L of CIP solution.
When this alarm is triggered refill the CIP tank and
reset the alarm in the alarm’s screen.
No
Not
Urgent
PAE ###
PCB related issue. Contact Voltea for support.
Contact
Voltea
Important
I2C
EC probe communication interrupted.
Yes
Important
ZERO EC
Conductivity reading less than 5
µ
S/cm for more than
30 seconds, unit goes to Idle.
Yes
Critical
TEMP. ERR
Water temperature reading out of range. Unit uses last
known temperature – Resolves automatically.
Yes
Important
8.3
D
EVICE INFO
In this section the product name, product model, firmware version, serial and IMEI number are available.