14
6.4
P
LACING LEAK SENSOR
The leak sensors are pre-installed. If the leak
sensors were removed during transit:
•
Take the two sensors and place them in the
clamps as shown in the image. The tip of the
sensor should be in contact with the leak
tray.
NOTE:
Leak tray should always be dry to avoid
triggering the leakage alarm and stopping the
system.
NOTE:
You can remove the leak sensors before
installing the module and re-install them right after.
6.5
P
LACING THE COVERS
.
Place the covers back and tighten the connections holding the covers in place.
NOTE:
Every connection has a spacer attached to it. Spacers should be between the covers and frame
before tightening.
6.6
W
ATER CONNECTIONS
Size 3/8” tubing should be used to connect the inlet to the IN connection on the side of the unit. The purified
(Out) water is discharged through the top 3/8’’ connection. Concentrate (Waste) is discharged through the
bottom 3/8’’ connection.
Connections are indicated by stickers.
6.7
P
OWERING THE SYSTEM UP
/
DOWN
•
A power cable is provided with the system.
•
Connect the cable to the power connection
on side of the unit.
•
I
powers ON the system and
O
powers
OFF.