High impact molded cabinet

This package should
contain:
1.

One dispenser --
pump, electronic
timer/control and
motor in high impact
molded cabinet.

2.

Supply tube (20 ft.)

3.

Drum tube and
holding tubes.

4.

Injection fitting.

5.

Mounting hardware.

6.

Cable ties (25).

7.

Tubing barbs (2).

8.

Battery holder (Models
1080 & 1085 only).

9.

AC adaptor (Models
1070 & 1075 only).

10. Instruction sheet.

Timer

Peristaltic pump

AutoDoseTM Programmable Dispensers From Lyn Distributing

Models 1060, 1065, 1070, 1075, 1080 & 1085: Operation & Maintenance

AutoDose

TM

 programmable dispensers are battery operated peristaltic pumping systems (convertible to AC power) which

run automatically at preset times as programmed on an electronic timer/control mechanism. Models vary as to the
pump's power source and the pump tubing material (see page 7 for specifications).

observe safety and handling instructions of the chemical manufacturers.

direct discharge away from you or other persons or into approved containers.

dispense cleaners and chemicals in accordance with manufacturer's instructions. Exercise
CAUTION when maintaining your equipment.

equipment clean for proper operation.

protective clothing and eyewear when working in the vicinity of all chemicals, filling or emptying
equipment or changing tubes.

re-assemble equipment according to instruction procedures. Be sure all components are firmly
screwed or latched into position. Assure that hoses and electrical wire are properly placed and
not kinked or pinched.

ALWAYS

ALWAYS

ALWAYS

KEEP

WEAR

ALWAYS

Please use this equipment carefully and observe all warnings and cautions.
******************************************************************* NOTE ***********************************************************

THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS

System installation ............................................................................................................................................. Pages 2-3

Installing the power supply ................................................................................................................................. Pages 2-3

Determining the proper dosage for application ......................................................................................................... Page 3

Programming the timer ....................................................................................................................................... Pages 3-4

Changing the pump tubing ....................................................................................................................................... Page 5

Troubleshooting ....................................................................................................................................................... Page 5

System parts diagram and list ................................................................................................................................. Page 6

System specifications ............................................................................................................................................. Page 7

Template for wall mounting system ......................................................................................................................... Page 8

TABLE OF CONTENTS

Page 1

Summary of Contents for AutoDose 1060

Page 1: ...rect discharge away from you or other persons or into approved containers dispense cleaners and chemicals in accordance with manufacturer s instructions Exercise CAUTION when maintaining your equipment equipment clean for proper operation protective clothing and eyewear when working in the vicinity of all chemicals filling or emptying equipment or changing tubes re assemble equipment according to ...

Page 2: ...through to allow the tubing to pass into the pipe Wrap the injection fit ting once with sealing tape Teflon and screw in the injection fitting Tighten to provide a positive seal 8 Determine where the discharge tube will be secured to walls tables etc Cut tubing the appropriate length for such installation Connect the tubing to the injection fit ting Be sure the tubing will be out of the way of tra...

Page 3: ...rate of a little more than 3 5 ounces per minute After the first few running hours the dispense rate will be approximately 3 5 ounces per minute and remain close to that for the balance of the practical battery life 40 total running hours The minimum dispensing time is one minute If a minimum dispense of less than 3 5 ounces is desired inquire about smaller capacity tubes 1 See the instructions fo...

Page 4: ...wing programs does not change the settings but you can change the program while you are reviewing it by using the 1 7 h and m buttons If you are reviewing a program when a programmed on event should take place the motor will not start until you switch the unit back to automatic In the case of an off event the dispenser will not stop until you switch the timer back to automatic mode 7 To change a p...

Page 5: ...event pumping 10 Place a dab of Tube Lube on the lower roller as shown Further lubing during operation is not needed 11 Replace the clear cover and install the two short screws into the brass inserts in the pump body 12 Put a cable tie on the inlet tube stem left side as viewed from front just below the pump housing This will prevent the tubing from walking through the pump as the pump operates 13...

Page 6: ...uired 2 a b c 4 3 1 Key Part Description 1 10069135 Lock replacement kit 2 10069136 Timer replacement kit 3 10069103 Timer cover clear 4 10006103 Motor gearbox 5 10069108 Wireharness 6 10069137 Door with lock 7 10069138 Inner body with wiring Black wire goes to motor terminal that is marked with a red dot NOTSHOWN 10016401 Tube connector barb kit 10016201 Drum tube kit Norprene 10016202 Viton 1001...

Page 7: ...illhelptoprovidetheproperdosingbyprovidingamoreconsistentpumpingrate USEONLYALKALINEBATTERIES CAUTION ALWAYSTURNTHEMODESWITCHTOTHE O POSITION OFF BEFORECHANGINGANYBATTERIES Tube Selection Guide TUBE DRAIN TREATMENT TYPE Viton Solvents Acids Norprene Bacterias Enzymes Detergents DispenserSpecifications PUMP Flow rate 100 cc approx 3 5 oz min Tube Model 1060 1070 1080 Norprene Models 1065 1075 1085 ...

Page 8: ...12 03 Centerline of cabinet T O P CENTER DRILL AT THESE POINTS TEMPLATE FOR WALL MOUNTING DISPENSER Page 8 ...