background image

 

 

 

 

 

 

 

WEH1500 

 

 

 

109901 

 

 

 

Summary of Contents for WEH1500

Page 1: ...WEH1500 109901...

Page 2: ...Bartscher GmbH Franz Kleine Str 28 D 33154 Salzkotten Germany Phone 49 5258 971 0 Fax 49 5258 971 120 Service hotline 49 5258 971 197 www bartscher com Version 1 0 Date of preparation 2023 12 01 EN 2...

Page 3: ...2 3 Declaration of Conformity 6 3 Transport Packaging and Storage 7 3 1 Delivery Check 7 3 2 Packaging 7 3 3 Storage 7 4 Technical Data 8 4 1 Technical Specifications 8 4 2 List of Components of the...

Page 4: ...ng of the appliance Additionally accident prevention occupational health and safety and legal regulations in force in the area the appliance is used apply Before you start using the appliance especial...

Page 5: ...the mains voltage To avoid short circuit the appliance should be kept dry If there are malfunctions during operation disconnect the appliance from the power supply Do not touch the appliance s plug wi...

Page 6: ...tal capabilities nor by persons with limited experience and or limited knowledge Children should be supervised to ensure that they are not playing with or switching on the appliance Improper Use Unint...

Page 7: ...idered to be an unintended use The following is an intended use Reduces limescale build up in an appliance and on washed items by reducing water hardness 1 4 Unintended Use An unintended use may lead...

Page 8: ...troduced by the user usage of unapproved spare parts We reserve the right to introduce technical modifications to the product intended for improvement of the appliance and its performance 2 2 Copyrigh...

Page 9: ...used to store the appliance when relocating or when shipping the appliance to our service point in the case of any damages The packaging and its elements are made of recyclable materials Particularly...

Page 10: ...ty appliances 1 Return value per cartridge 0 Operating pressure 2 6 Salt stock in brine tank in kg 20 Salt consumption in kg regeneration 0 7 Regeneration duration in min 45 Dimensions W x D x H in mm...

Page 11: ...Technical Data 109901 9 30 EN 4 2 List of Components of the Appliance Fig 1 1 Control valve with digital display 2 Filter cartridge 3 Brine tank cover 4 Brine tank 5 Housing 6 Connections...

Page 12: ...t the set time During regeneration 60 min unsoftened water is available The regeneration process consists of 4 cycles 1 Regenerating agent replenishment 2 Rinsing with the regenerating agent solution...

Page 13: ...28 8 285 8 16 938 21 3 30 6 303 6 17 882 22 5 32 4 321 5 18 833 23 8 34 2 339 3 19 789 25 0 36 0 357 2 20 750 26 3 37 8 375 1 21 714 27 5 39 6 392 9 22 682 28 8 41 4 410 8 23 652 30 0 43 2 428 6 24 6...

Page 14: ...lations for the use of water of the public utility at a site All parts in contact with the treated water must be made of waterproof material Ensure that a soil drainage is installed at the water treat...

Page 15: ...nish the salt Salt should be replenished on time to avoid using unsoftened water When the display shows the SALT alarm the salt in the brine tank can be used for 2 or 3 more regenerations Bypass The b...

Page 16: ...AY appears in the display To switch the holiday mode off press the button until the HOLIDAY message is no longer displayed If the control valve does not detect water consumption greater than 6 LPM lit...

Page 17: ...alized personnel Unpack the appliance and discard the entire packing material Never remove the rating plate or any warning signs from the appliance Before installing the water softening system the app...

Page 18: ...e must be kept in its open original packaging for at least 24 hours before it is put into operation at the specified ambient temperature Preparation for Installation The user must make the following p...

Page 19: ...1 Water supply line with 3 4 connection and shut off valve 2 Cold water supply 3 Mechanical cleaning filter 4 Electrical socket 5 Control valve 6 Brine tank 7 Overflow drain elbow 8 Flexible regenerat...

Page 20: ...e system ATTENTION The sewage pipe must be large enough to allow 5 l m of rinse water to drain The drain pipe must be rigid enough not to break and lead to blockages and overflowing of the brine tank...

Page 21: ...s and enter the correct value Based on this the system will calculate the capacity after which regeneration should begin The control valve is set by default so that regeneration takes place at 2 00 AM...

Page 22: ...reventing anyone from threading on it or tripping against it 5 3 Operation Display Messages Fig 5 a current time b information about the day of the week c appliance M3 flow rate PPM dH FH water hardne...

Page 23: ...ng to the operating position j setting mode At the controls in the data settings k valve type SOFT softening valve FILTE filter valve Control Keys Fig 6 Time programming menu Short press enter user se...

Page 24: ...Functions When the power is switched off in the operating position the control valve remains in the same position even after reaching regeneration The battery processor and flow meter operate normall...

Page 25: ...le below or contact the service department 1 To enter the setting mode press the button 2 In the home screen press the button to set the time Fig 8 The hours indicator starts flashing 3 Press the or b...

Page 26: ...The overrun day indicator starts flashing 9 Press the or button to set the overrun day 10 Press the button to save the setting Fig 12 The regeneration time indicator starts flashing 11 Press the or bu...

Page 27: ...15 The water hardness indicator starts flashing 14 Set the degree of water hardness dH on the inlet by pressing the or button 15 Press the button to save the setting Fig 16 The electric power indicat...

Page 28: ...Fig 18 Manual regeneration initiation 19 Press the button in the home screen for 5 seconds The control valve initiates regeneration immediately Press the button again to proceed to the next stage of t...

Page 29: ...109901 27 30 EN The optical sensor does not receive a signal Fig 21 The electric motor is blocked or locking the wrong starting position Fig 22 Digital display is not well connected to the control va...

Page 30: ...s descriptions of possible causes and solutions to malfunctions or errors during operation of the appliance When malfunction cannot be removed contact the technical service In such a case provide arti...

Page 31: ...nually The appliance does not take salt solution Clogged drain line or flow regulator Clean the drain line and flow regulator Clogged injector Clean injector replace injector housing No water in the b...

Page 32: ...ppliances must be disposed of and recycled in a correct and environmentally friendly manner You must not dispose of electric appliances with household waste Disconnect the appliance from the power sup...

Reviews: