6 Rack Installation of the Transmitter
6.3 Output Connector Pin-Out
Table 6-1 shows the high-voltage output jack's pin-out and mating connector.
Determine the conductor length needed to connect the transmitter output to the
external signal protection relay and ground control unit assemblies. Use a minimum of
18 AWG conductors rated minimum 600 V, minimum 80ºC, and the colors specified in
Figure 6-1.
NOTE
Discharge the above if the relay box is installed.
WARNING
Turn the rear power switch off before handling this module’s
connectors. The high-voltage output may be at 300V AC or 450V
DC.
Output Jack
Pin
1
2
3
Connection
Signal High
Signal Low
N.C.
Wire color
Blue
White
----
1
2
2
3
3
1
Mating Connector
Figure 6-1 Pin-Out for the Output Jack and Mating Connector
6.4 Attaching the Rock Mounting Brackets
The transmitter ships with three sizes of standard and adjustable mounting brackets,
allowing for installation in 19, 23, or 24-inch racks. The FLS-2 transmitter ships with
the 19-inch standard rack mounting brackets already attached. The adjustable rack
mounting bracket kit allows you to adjust the horizontal front-to-back position of the
transmitter up to 5.25-inches (133.4mm). Figure 6-2 shows the left bracket for the
adjustable brackets.
Measure the rack width and use the following instructions if you need to change the
bracket size.
To remove and install the rack mounting brackets:
1. Remove the attached mounting brackets using the Philips-head screwdriver and
save the flat-head screws.
2. Attach the new brackets to the same place with the flat-head screws.