58
0B Set flow temperature for external demand
!
Display
Value
Explanations
Limited by boiler-specific parameters
70 °C
0B:70
... °C
0B:0 to
0B:127
14 Fault message module 1
Display
Value
Explanations
Without
14:0
With
14:1
Recognised automatically.
15 Fault message module 2
Display
Value
Explanations
Without
15:0
With
15:1
Recognised automatically.
16 Burner control unit connection
Display
Value
Explanations
Other
16:0
Never adjust
KM-BUS
16:1
CAN bus
16:2
1A Solar control unit
Display
Value
Explanations
Without
1A:0
With Vitosolic 100
1A:1
With Vitosolic 200
1A:2
Recognised automatically.
Solar control module, type SM1, without
auxiliary function
1A:3
Solar control module, type SM1, with auxili-
ary function, e.g. central heating backup
1A:4
Differential temperature control 2 with temperature
sensor
/
and
aÖ
1B Pump module PM1
Display
Value
Explanations
Without
1 B:0
With
1 B:1
Recognised automatically.
20 Flow temperature sensor for low loss header
Display
Value
Explanations
Without
20:0
With
20:1
Recognised automatically.
Parameter
General
(cont.)
5863679
Parameter
Содержание Vitotronic 11 CC1E
Страница 111: ...111 PCB 230 V Fig 46 Connection and wiring diagrams Connection and wiring diagram cont 5863679 Appendix...
Страница 118: ...118 5863679...
Страница 119: ...119 5863679...