Coding in the delivered condition
Possible change
30:1
Internal variable speed
circulation pump (auto-
matic adjustment)
30:0
Internal circulation pump
without variable speed
(e.g. temporarily for ser-
vice)
31:...
Set speed of the inter-
nal circulation pump
when operated as boiler
circuit pump in %, de-
faulted by the boiler
coding card
31:0
to
31:100
Set speed adjustable
from 0 to 100 %
32:0
Influence of the signal
"External blocking" on
circulation pumps: All
pumps in control func-
tion
32:1
to
32:15
Influence of the signal
"External blocking" on
circulation pumps: see
the following table
Note
Generally, the burner will be blocked when signal "External blocking" is
enabled.
Value
address
32: ...
Internal circu-
lation pump
Heating circuit
pump
Heating circuit
without mixer
Heating circuit
pump
Heating circuit
with mixer
Circulation
pump for cylin-
der heating
0
Control funct.
Control funct.
Control funct.
Control funct.
1
Control funct.
Control funct.
Control funct.
OFF
2
Control funct.
Control funct.
OFF
Control funct.
3
Control funct.
Control funct.
OFF
OFF
4
Control funct.
OFF
Control funct.
Control funct.
5
Control funct.
OFF
Control funct.
OFF
6
Control funct.
OFF
OFF
Control funct.
7
Control funct.
OFF
OFF
OFF
8
OFF
Control funct.
Control funct.
Control funct.
9
OFF
Control funct.
Control funct.
OFF
10
OFF
Control funct.
OFF
Control funct.
11
OFF
Control funct.
OFF
OFF
12
OFF
OFF
Control funct.
Control funct.
13
OFF
OFF
Control funct.
OFF
14
OFF
OFF
OFF
Control funct.
15
OFF
OFF
OFF
OFF
Code 2
(cont.)
47
Coding
5692
779
GB
Содержание VITOLADENS333-F
Страница 96: ...A1 Main PCB A2 Power supply unit Connection and wiring diagram external connections 96 Designs 5692 779 GB...
Страница 101: ...Parts lists cont 101 Parts lists 5692 779 GB...
Страница 102: ...Parts lists cont 102 Parts lists 5692 779 GB...
Страница 103: ...Parts lists cont 103 Parts lists 5692 779 GB...
Страница 104: ...Parts lists cont 104 Parts lists 5692 779 GB...
Страница 105: ...Parts lists cont 105 Parts lists 5692 779 GB...