Press the following keys:
1.
c
"Select heating circuit" is
displayed.
2.
d
to confirm; wait approx.
4 s.
3.
c
press again.
4.
a
/
b
for the required operating
condition.
5.
d
Scanning is completed.
The following operating conditions can be scanned, subject to the actual
system equipment level for heating circuit A1 and heating circuit with
mixer M2:
Display screen
Explanation
Subscriber no.
Programmed user number in the LON system
Holiday program
If holiday program entered.
Departure date
Date
Return date
Date
Outside temperature, ... °C
Actual value
Boiler water temp., ... °C
Actual value
Flow temperature, ... °C
Actual value (only with heating circuit with mixer
M2)
Standard
Room temperature, ... °C
Set value
Room temperature, ... °C
Actual value
Ext. set room temp, ... °C
With external hook-up
DHW temperature, ... °C
Actual DHW temperature
Mixed flow temp., ... °C
Actual value, only with low loss header
Burner, ...h
*
1
Hours run
Burner st 1 ...h
Hours run
Burner st 2 ...h
Hours run
Burner starts, ...
*
2
Actual value
Time
Date
Burner OFF/ON
Burner stage 1 OFF/ON
Burner stage 2 OFF/ON
Int. pump OFF/ON
Output 20
Heating circuit pump OFF/ON If an external extension or extension kit for one
heating circuit with mixer is installed
Scanning operating conditions and sensors
65
Service scans
5692
779
GB
*1
Reset hours run and burner starts after a service. The values can be reset individually to
"0" by pressing
e
.
*2
Party mode ends
automatically
in heating program "
rw
" when the system changes
over to operation with standard room temperature.
Содержание VITOLADENS333-F
Страница 96: ...A1 Main PCB A2 Power supply unit Connection and wiring diagram external connections 96 Designs 5692 779 GB...
Страница 101: ...Parts lists cont 101 Parts lists 5692 779 GB...
Страница 102: ...Parts lists cont 102 Parts lists 5692 779 GB...
Страница 103: ...Parts lists cont 103 Parts lists 5692 779 GB...
Страница 104: ...Parts lists cont 104 Parts lists 5692 779 GB...
Страница 105: ...Parts lists cont 105 Parts lists 5692 779 GB...