2.
Activate the venting program via
coding "2F:1".
Note
To call up code 1 and for setting the
coding address, see page 43.
For function and sequence of the
venting program, see page 88.
When the venting program is
enabled, the display shows "Entlüf-
tung" (Venting).
3.
Check the system pressure.
Filling the siphon with water
1.
Remove retaining clip
A
and
siphon
B
.
If required, push insert
C
up.
2.
Fill siphon
B
with water.
3.
Fit siphon
B
and secure with
retaining clip
A
.
Further details regarding the individual steps
(cont.)
9
Commissioning, inspection, maintenance
5692
779
GB