VD120 Series Inverter User Manual Parameter Description
-
77
-
T
T
Set frequency(f)
Output frequency(Hz)
Time(t)
Rated frequency(f
b
)
S curve acceleration/deceleration B diagram
Fig 6-4 S curve acceleration/deceleration diagram
F2 Motor 1 Parameter
F2-00
Motor Type Selection
0: Ordinary asynchronous motor
1: Frequency conversion
asynchronous motor
0
◎
F2-01
Rated Motor Power
0.1kW~11.0kW
Model
dependent
◎
F2-02
Rated Motor Voltage
1V~1000V
Model
dependent
◎
F2-03
Rated Motor Current
0.01A~100.00A
Model
dependent
◎
F2-04
Rated Motor Frequency
0.01Hz~max frequency
Model
dependent
◎
F2-05
Rated Motor Rotation
Speed
1RPM~65535RPM
Model
dependent
◎
The above function code for parameters of motor nameplates, whether using V/D control or vector
control, all need according to the motor nameplate set the related parameters accurately.
In order to obtain better performance of V/F or vector control, motor parameter tuning is required, and
the accuracy of the adjust results, close relation to correctly set motor nameplate parameters.
F2-06
Asynchronous Motor
Stator Resistance
0.001Ω~65.535Ω
Tune
parameter
◎
F2-07
Asynchronous Motor
Rotor Resistance
0.001Ω~65.535Ω
Tune
parameter
◎
F2-08
Asynchronous Motor
Leakage Inductive
Reactance
0.01mH ~655.35mH
Tune
parameter
◎
Содержание VD120 Series
Страница 2: ......