Function Parameter Table VD120 Series Inverter User Manual
-
52
-
5: Communication setting
6: Reserved
7: Reserved
8: Keypad Potentiometer (the full
scale of option 1~7 corresponding
digital setting of A0-02)
A0-02
Torque Digital
Setting under
the Torque
Control Mode
-200.0%~2000%
100.0%
○
A0-03
Max Frequency
Source
Selection
under the
Torque Control
Forward
0: Digital setting (A0-04)
1: AI1
2: Reserved
3: Reserved
4: PULSE
5: Communication setting
6: Keypad potentiometer
0
◎
A0-04
Max Frequency
Digital Setting
under the
Torque Control
Forward
0.00Hz~max frequency
50.00Hz
○
A0-05
Max Frequency
Source
Selection
under the
Torque Control
Reverse
0: Digital setting (A0-06)
1: AI1
2: Reserved
3: Reserved
4: PULSE
5: Communication setting
6: Keypad potentiometer
0
◎
A0-06
Max Frequency
Digital Setting
under the
Torque Control
Reverse
0.00Hz~max frequency
50.00Hz
○
A0-07
Torque Control
Acceleration
Time
0.00s~650.00s
0.00s
○
A0-08
Torque Control
deceleration
Time
0.00s~650.00s
0.00s
○
A0-09
Starting Torque
Setting
0.0%~100.0%
10.0%
◎
A0-10
Excitation
Current
Coefficient
20.0%~150.0%
100.0%
◎