Function Parameter Table VD120 Series Inverter User Manual
-
26
-
F5-13
DI1 Close
Delay Time
0.0s~3600.0s
0.0s
◎
F5-14
DI2 Close
Delay Time
0.0s~3600.0s
0.0s
◎
F5-15
DI3 Close
Delay Time
0.0s~3600.0s
0.0s
◎
F5-16
DI1 Open
Delay Time
0.0s~3600.0s
0.0s
◎
F5-17
DI2 Open
Delay Time
0.0s~3600.0s
0.0s
◎
F5-18
DI3 Open
Delay Time
0.0s~3600.0s
0.0s
◎
F5-19
Terminal
UP/DOWN
change rate
0.001Hz/s~65.535Hz/s
1.000Hz/s
○
F5-20
AI Curve
Selection
AI1 curve selection
1: Curve 1
(2 point, see F5-22~F5-26)
2: Curve 2
(2 point, see F5-27~F5-31)
3: Curve 3
(2 point, see F5-32~F5-36)
4: Curve 4
(4 point, see b2~00-b2-07)
5: Curve 5
(4 point, see b2-08~b2-15)
1
○
F5-21
AI is Lower
than Min Input
Setting
Selection
AI1 is lower than min input setting
selection
0: Corresponding to the min input
setting
1: 0.0%
0
○
F5-22
AI Curve 1 Min
Input
-10V~F5-24
0.00V
○
F5-23
Corresponding
Setting of AI
Curve 1 Min
Input
-100.0%~+100.0%
0.0%
○
F5-24
AI Curve 1 Max
Input
F5-22~+10.00V
10.00V
○
F5-25
Corresponding
Setting of AI
Curve 1 Max
Input
-100.0%~+100.0%
100.0%
○
F5-26
AI 1 Filter Time
0.00s~10.00s
0.10s
○
Содержание VD120 Series
Страница 2: ......