Parameter Description VD120 Series Inverter User Manual
-
104
-
Bit10: Reserved
Bit11: Reserved
Bit12: Count value
Bit13: Length value
Bit14: Load speed display
BIT15: PID setting
F7-03
LED Running Display
Parameter 2
0000~0xFFFF
Bit00: PID feedback
Bit01: PLC stage
Bit02: PULSE input frequency (kHz)
Bit03: Running frequency 2 (Hz)
Bit04: Set torque (0.%)
Bit05: Voltage before AI1 correction (V)
Bit06: Reserved
Bit07: Reserved
Bit08: Line speed
Bit09: Current power on time (Hour)
Bit10: Current running time (Min)
Bit11: PULSE input frequency (Hz)
Bit12: Communication setting value
Bit13: Reserved
Bit14: Main frequency A display (Hz)
Bit15: Auxiliary frequency B display (Hz)
0x0000
○
Inverter in run condition, parameter display is subjected to the function code, which is a 16 bit binary
number, if one bit is 1, the corresponding parameters of the bit at run time, can see through the shift
key. If the bit is 0, then the corresponding parameters will not be displayed. The lower the bit is, the
higher the display priority is.
Comparison table of operating display low bit
F7-02
Comparison table of operating display low bit
F7-03
Corresponding
display parameter
Hexadecimal
Corresponding display
parameter
Hexadecimal
Running
frequency(Hz)
0x0001
PID feedback
0x0001
Set frequency(Hz)
0x0002
PLC stage
0x0002
Bus voltage(V)
0x0004
PULSE input pulse
frequency
0x0004
Output voltage(V)
0x0008
Running frequency
0x0008
Output current(A)
0x0010
Set torque (%)
0x0010