Function Parameter Table VD120 Series Inverter User Manual
-
32
-
Bit06: Reserved
Bit07: Count value
Bit08: Length value
Bit09: PLC stage
Bit10: Load speed
Bit11: PID setting
Bit12: Pulse input frequency (kHz)
Bit13: Set torque (0.1%)
F7-05
The Second
Line LED
Running
Display
Parameters
0~15 corresponding bit0~bit15 of
F7-02
16~31 corresponding bit0~bit15 of
F7-03
4
○
F7-06
The Second
Line LED Stop
Display
Parameters
0~13 corresponding bit0~bit13 of
F7-05
1
○
F7-07
Load Speed
Display
Coefficient
0.0001~6.5000
1.0000
○
F7-08
Load Speed
Display
Decimal Places
0: 0 bit decimal place
1: 1 bit decimal place
2: 2 bit decimal place
3: 3 bit decimal place
1
○
F8 Protection Parameters
Function
Code
Parameter
Name
Setting Range
Factory
Default Value
Property
F8-00
Motor Overload
Protection
Selection
0: Disabled
1: Enabled
1
○
F8-01
Motor Overload
Protection Gain
0.20~10.00
1.00
○
F8-02
Motor Overload
Warning
Coefficient
50%~100%
80%
○
≤11kW: 1
F8-06
Overvoltage/ov
er current Stall
Mode Selection
0: Mode 0
1: Mode 1
>11kW: 0
◎
F8-07
Overvoltage
Stall Proportion
Gain
0: Disabled
1~100
10
○
F8-08
Overvoltage
Stall Integral
Gain
0~100
5
○