Important Safeguards – Outdoor Use

 

GRAPHIC SYMBOL EXPLANATION 

The lightening bolt symbol alerts the user to the presence of 

dangerous voltage that may present the risk of electric shock. 

 

The exclamation point symbol alerts the user to the presence 

of important operating and maintenance instructions. 

 

1. Read Instructions -

 Read all safety and operating instruc-

tions before the product is operated. 

2. Retain Instructions -

 Retain all safety and operating in-

structions for future reference. 

3. Heed Warnings -

 Pay attention to all product warnings. 

4. Follow Instructions -

 Follow all operating instructions. 

5. Cleaning -(Do not use caustic, abrasive or aerosol 

cleaners) 

 

a) 

For units that CAN BE DISCONNECTED from the power 

source, use a damp cloth for cleaning. 

b) For

 

units that CANNOT BE DISCONNECTED from the 

power source, use a damp cloth for cleaning and do not 

allow moisture or liquids to enter vents. 

6. Attachments -

 Use only UL Listed Vicon recommended 

attachments to prevent unit damage and personal injury. 

7. Water and Moisture -

 Use only products designed for out-

door environments where they will be exposed to water or 

moisture. 

8. Accessories -

 Do not place the unit on an unstable surface 

to avoid falling. Use only UL Listed Vicon recommended mounting 

accessories. 

9. Ventilation -

 Do not block ventilating slots and openings as 

they ensure reliable operation. Do not place the unit near a 

heat source or into an enclosure unless recommended by 

Vicon. 

10. Power Sources -

 The product should only be operated 

from the recommended power source. Use only a UL Class 2 

indoor/dry or Class 3 outdoor/wet power supply. 

11. Grounding -

 Only products equipped with a 3-prong 

grounded plug should be inserted into a grounded power outlet. 

Contact an electrician to replace an obsolete outlet. Do not 

force a plug into a non-grounded outlet. 

12. Power Cord Protection -

 Power supply cords should not 

be routed in trafficked areas or in tight spaces where they will 

be pinched or used to bear weight. Allow some slack in the 

cord where it enters the unit. 

 

 

13. Outdoor Cable Grounding -

 Use only grounded outdoor 

cables to protect against voltage surges and static charges. 

Section 810 of the National Electrical Code, ANSI/NFPA 70-

1984, provides information on proper grounding of the lead-in 

wire to an antenna discharge unit, size of grounding conduc-

tors and the requirements of grounding electrodes. 

14. Lightning -

 Disconnect the product from its power source 

and cable system when possible to prevent damage due to 

lightning and power-line surges. 

15. Power Lines -

 Do not locate outside cables over power or 

utility lines where they can fall and make direct contact. Con-

tact with power lines can be fatal. 

16. Overloading -

 Do not overload wall outlets and extension 

cords to prevent risk of fire and electric shock. 

17. Object and Liquid Entry -

 Never probe through, or spill 

liquid into, enclosure openings to prevent risk of fire or electric 

shock. 

18. Servicing -

 Refer all servicing to qualified service person-

nel. 

19. Damage Requiring Service -

 Obtain service when: 

 

a) 

The power-supply cord or plug is damaged. 

b)  Objects have fallen or liquid has been spilled into the 

product. 

c)  The product is not designed for outdoor use and has 

been exposed to water or moisture. 

d) 

The product does not operate per the operating instruc-

tions. Perform Vicon recommended adjustments, modifi-

cations and troubleshooting only to avoid unit damage 

and personal injury. 

e) 

The product has been dropped. 

f) 

The product shows a significant change in performance. 

 

20. Replacement Parts -

 Use only Vicon specified replace-

ment parts or an approved equivalent to prevent unit damage 

and injury. 

21. Safety Check -

 Request safety checks to be performed 

following repair or maintenance to verify proper operation. 

22. ESD Precaution -

 Take all normal electrostatic discharge 

precautions to avoid component damage during installation 

and operation. 

23. For 230 VAC Devices Only -

 When the disconnect device 

is not incorporated in the equipment or when the plug on the 

power supply is intended to serve as the disconnect device, 

follow the guidelines below: 

a)  For permanently connected 230 VAC units, a readily 

accessible disconnect device must be incorporated into 

the site wiring. 

b)  For 230 VAC units with a plug, the outlet must be in-

stalled near the unit and be easily accessible. 

 

 

Содержание I-Onyx MPD-980DN

Страница 1: ...d to be used in life critical situations and must not be used for this purpose Copyright 2011 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and...

Страница 2: ......

Страница 3: ...off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Reloc...

Страница 4: ......

Страница 5: ...Introduction 1 Connectors and Controls 2 Installation 3 Camera Configuration 9 ViconNet Configuration 26 Troubleshooting 31 Appendix 32 Maintenance 44 Shipping Instructions 44 Network Cable 45 Technic...

Страница 6: ...13 Outdoor Cable Grounding Use only grounded outdoor cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides information on p...

Страница 7: ...64 compression technology reducing file sizes and conserving bandwidth With MPEG 4 and M JPEG compatibility video streams can also be transmitted in any of these formats for versatile applications The...

Страница 8: ...alarms in Output is not supported by ViconNet for future use LOCAL STORAGE A slot for an SD card is provided for local storage VIDEO FORMAT A switch is provided to select 60 Hz or 50 Hz designated NT...

Страница 9: ...A bottom base is in cluded with the camera dome for securing it to a ceiling or wall Mounting to a Ceiling 1 Attach the supplied alignment sticker to the ceiling 2 Using the 10 circles on the sticker...

Страница 10: ...into the wall Insert the four supplied plastic anchors into the holes 3 Insert the four supplied screws through the four holes on the bottom base and into the corresponding holes in the wall secure t...

Страница 11: ...ircles on the sticker drill at least 3 pilot holes into the ceiling Insert the supplied plastic anchors into the holes 4 Mount the camera dome into the ceiling and feed the cables through the cable ac...

Страница 12: ...screw terminal block 2 The camera allows the transmission of power and data via a single Ethernet cable the Ethernet cable should meet the specs of UTP Category 5 and not exceed 100 meters in length...

Страница 13: ...then select Indoor or Outdoor for the environment Adjusting the Camera Position The camera dome provides a 3 axis mechanism for precise positioning of the camera s angle of view 1 Loosen the pan adju...

Страница 14: ...n the focus controller to adjust the focus range Upon completion tighten the focus controller Final Installation After the camera and lens are adjusted complete the camera dome installation as follows...

Страница 15: ...ends to connect the camera directly to the PC using a crossover cable or locally to bypass the DHCP server Refer to Appendix for instructions on locating cameras with unknown IP addresses Network Sett...

Страница 16: ...he web browser in MPEG 4 mode when in JPEG mode some of the video controls are eliminated Vicon recommends using Internet Explorer If Firefox is being used Quicktime must be installed to view video Fo...

Страница 17: ...the menu Detailed information is only displayed when a function is selected Functions that are only available in Advanced mode are noted as Advanced Mode Upon opening the camera in the browser a live...

Страница 18: ...ure of the transmission to destinations in different subnet Vicon recommends using 254 as the last octet Primary DNS The primary domain name server that translates hostnames into IP addresses Secondar...

Страница 19: ...Two way audio Two way audio port The default port is 5060 The user can change this value from 1025 to 65535 After being changed the external Two Way audio client program must be changed to the same s...

Страница 20: ...iconNet Multicast RTCP audio port The audio channel port for multicast RTCP this must be the port number of multicast audio port plus 1 Default is 5563 it can be changed to a value between 1025 and 65...

Страница 21: ...rver Assign the IP address or domain name of the time server Leaving the text box blank connects the camera to the default time servers Update interval Select hourly daily weekly or monthly update wit...

Страница 22: ...tion is to re store to the original factory default settings Manage Privilege Advanced Mode The privileges of Operators and Viewers can be modified for PTZ control and Digital Output Check or uncheck...

Страница 23: ...ake sure of the service charges Host name If the User wants to use DDNS service this field must be filled Input the host name that is registered in the DDNS server User name The User name field is nec...

Страница 24: ...ws two lists for permission con trol Allowed list and Denied list Only those users whose IP address is in the Allowed list and not in the Denied list can connect to the video server or camera to recei...

Страница 25: ...that the VMC requires JPEG mode Video Settings Enter the name of the camera in the Video title field In the Color field select Color or B W For Power line frequency select 60 Hz or 50 Hz to match the...

Страница 26: ...brightness contrast saturation and sharpness 5 to 5 the value 0 indicates auto tun ing and white balance Press Preview to view the image and fine tune the settings When the image is ac ceptable press...

Страница 27: ...he region of interest and output frame rate for each the multiple streams For Stream 1 and 2 users define the Region of Interest viewing region and the Output Frame Rate size of the live view window F...

Страница 28: ...for JPEG mode For Video Quality in MPEG 4 H 264 mode select Constant bit rate or Fixed quality only the fixed video quality is available in JPEG mode Constant bit rate maintains the bandwidth utilizat...

Страница 29: ...5 5 5 Record Size per Second MBytes 0 05055 0 07775 0 107 0 159 0 1975 0 225 Record Size per Minute MBytes 3 033 4 665 6 42 9 54 11 85 13 5 Record Size per Hour MBytes 181 98 279 9 385 2 572 4 711 81...

Страница 30: ...w Click on the Save button to save the settings A graphic bar will rise or fall depending on the image variation A green bar means the image variation is under monitoring level and a red bar means the...

Страница 31: ...etwork type on network screen Factory default Click on Default button to restore the factory default settings Any changes made so far will be lost and the system will be reset to the initial factory s...

Страница 32: ...party license to be used in the system Note I Onyx MPD 980DN O cameras only need to be added once in the Nucleus for the entire system 1 From the ViconNet Main window click The Setup Site Selection w...

Страница 33: ...C and UPnP Framework is enabled checked in Windows Firewall Exceptions If UPnP is not available on the OS click on Add I Onyx 9XX Cameras to add cameras manually See procedure below Some OS PC may hav...

Страница 34: ...in its browser It is recommended that the user be administrator level to be able to access all camera features 8 Click the button This is a direct link to the browser for that camera Below is a sample...

Страница 35: ...ndow An Undo button is provided To edit an existing camera 1 Click the button on the I Onyx 9xx and Third Party Camera settings screen 2 Select the camera that you want to edit The Camera Details area...

Страница 36: ...s and system bandwidth mapping Bandwidth limitations on ports connected to workstations using 100 or 1000 Mbps Workstation capabilities such as processing speed disk write speed and display card stren...

Страница 37: ...tore the factory default settings Sometimes resetting the system sets the system back to normal state If the system problems re main after reset restore the factory settings and install again RESET Pr...

Страница 38: ...re are controls for volume microphone snapshot and full screen IR Illuminators Click on IR Illuminators to turn on the LEDs for 20 sec PTZ controls The camera supports both digital e PTZ and mechanica...

Страница 39: ...t loss and produces a more accurate video display With this protocol however the real time effect is worse than that with the UDP protocol s The HTTP protocol allows the same quality as TCP protocol b...

Страница 40: ...is defined a schedule is setup the Server is where the media resulting from the event is stored Email FTP HTTP or Network Storage and Media is how the event is captured snapshot video clip or system l...

Страница 41: ...l input trigger type The kinds of triggers supported are Video motion detection Select the motion detection windows that need to be monitored motion detection windows must be configured first Periodic...

Страница 42: ...ult mail server is set to 25 this can be manually changed Click Test to make sure settings are correct Click Save to enable settings and Close to exit FTP Server address Domain name or IP address of t...

Страница 43: ...to exit Video Clip Source The source of video clip Pre event recording Interval of pre event recording in seconds up to 9 There are two limitations for video clip file Maximum duration The maximum re...

Страница 44: ...fail local storage SD card as the trigger source The weekly and time schedules are provided Sun Sat Select the days of the week to record Time Select Always or input the time interval 24 hr format Des...

Страница 45: ...MPD 980DN O Camera Dome Local Storage Advanced Mode This screen manages the local storage SD card status and control and searching and viewing recorded files to playback download etc are configured Sy...

Страница 46: ...o allow the unit to receive a log from remote machine Check Enable remote log and input the IP address and port number of the log server to enable the remote log facility Current log displays the curr...

Страница 47: ...zard is designed with a user friendly interface When the wizard is opened the interface will display a list of cameras connected to the system 1 Run the Installation Wizard 2 under the Software Utilit...

Страница 48: ...you were instructed by Vicon technical support to update the camera firmware obtain the upgrade files from Vicon and follow these steps Go to the Maintenance screen under Configuration Go to the Upgra...

Страница 49: ...Setting Full Image Video quality settings for stream 1 H 264 Frame size 1600x1200 Maximum frame rate 15 fps Intra frame period 1 S Video quality Fixed quality Good Constant bit rate not selected set t...

Страница 50: ...or returns from countries in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the f...

Страница 51: ...re best suited for Ethernet network applications Choose a Belden cable type by referring to the characteristics listed below The Table below should be used as a guide line when cables other than Belde...

Страница 52: ...ensation Supports priva cy masks Up to 30 fps at 800 x 600 up to 15 fps at 1600 x 1200 Live viewing for up to 10 clients IP address filtering HTTPS encrypted data transmission 802 1X port based authen...

Страница 53: ...epaid in accordance with policy The Company will not be obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the Company are not defective or any equip...

Страница 54: ...quarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5...

Отзывы: