1851
Hardware watchdog has occurred.
Possible Cause:
• Noise issue.
Possible Solution:
• Check grounding to the IOF Card.
1852
Power loss interrupt failed (should never happen).
Possible Cause:
• A hardware or software problem.
1853
Invalid MAC Address - The Ethernet port is disabled.
Possible Cause:
• Manufacturing did not properly set the MAC address.
Possible Solution:
• Replace the CPUC Card.
1854
LU/LD stuck error.
• Magnet placement.
• Noise on Car CAN.
• Car CAN loading.
• Failed TSM Card.
1857
Software error - The system attempted to validate an I/O
prior to the I/O database being initialized (should never hap-
pen).
—
1858
Gate contact did not close.
—
1859
Discrete SPI HW failure - A CPU/IOF hardware failure.
• Check F1 on the IOF Card.
• Reload generic and job software.
• Replace the IOF Card.
1860
Inspection node offline.
• DPIA communication issue.
1861
The power-on self test failed.
—
1862
An invalid generic software version - The software version
does not match the job number. The car is shutdown until the
valid generic software is installed.
—
1865
A job file image is missing.
• Reload generic and job software.
1866
Flash job file image is corrupted.
• Reload generic and job software.
1867
The battery-backed RAM job file is corrupt.
• Reload generic and job software.
1868
DZ1 is stuck active during a run.
• Check the selector.
1869
DZ2 is stuck active during a run.
• Check the selector.
1870
Stuck car call detected.
—
1878
Stuck hall call button detected.
—
1920
Safety processor configuration invalid - At power-up, the CPU
Card detects an invalid IOF Card configuration.
• Use the SPC Command.
1921
Safety processor not online - At power-up, CPU did not
detect IOF Card safety processor communicating over car
CANbus.
• Communication disruption of the Car CAN Channel.
• A defective CPU.
• A defective IOF Card.
1922
NTSD processor not online.
• Communication disruption of the Car CAN Channel.
• A defective IOF Card.
1925
SP I/O mismatch with CPU.
—
1926
NP I/O mismatch with CPU.
—
1955
LULDM has detected an illegal state based on LUO and LDO
outputs.
Possible Causes:
• LD Relays are Bad.
• Wiring Issue: LUO, LDO, or LULDM I/O Circuits.
Possible Solutions:
• Reset through Inspection Operation.
3001
A call was lost because a car went out of service.
—
3003
The emergency phone detected failure of the phone line.
—
Code
Description
(cont.)
Possible Causes/Solutions
(cont.)
Содержание ICON 32
Страница 1: ...Controller...
Страница 3: ...INSTALLATION SECTION...
Страница 4: ...INSTALLATION SECTION...
Страница 39: ...ADJUSTMENT SECTION...
Страница 40: ...ADJUSTMENT SECTION...
Страница 42: ...2 2 Vertical Express Printed in USA April 2020 Contents Adjustment Section This page intentionally left blank...
Страница 83: ...DIAGNOSTICS SECTION...
Страница 84: ...DIAGNOSTICS SECTION...
Страница 86: ...3 2 Vertical Express Printed in USA April 2020 Contents Diagnostics Section This page intentionally left blank...
Страница 131: ...TROUBLESHOOTING SECTION...
Страница 132: ...TROUBLESHOOTING SECTION...
Страница 134: ...4 2 Vertical Express Printed in USA April 2020 Contents Troubleshooting Section This page intentionally left blank...
Страница 165: ...SERVICE INFORMATION SECTION...
Страница 166: ...SERVICE INFORMATION SECTION...
Страница 168: ...5 2 Vertical Express Printed in USA April 2020 Contents Service Section This page intentionally left blank...
Страница 205: ...REFERENCE SECTION SERVICE REFERENCE SECTION...
Страница 206: ...REFERENCE SECTION...
Страница 208: ...5R 2 Vertical Express Printed in USA April 2020 Contents Reference Section This page intentionally left blank...