DIAGNOSTICS
Vertical Express Product Manual
3-9
88500 v.1.0
Diagnostics Section
Adjustments
This manual shows only the parameters that have an operational relevance to the ICON32. The UIT may have
additional parameters available, which should not effect the controller operation.
H17
floor
1–nf
Flooded Pit Sensor 1 Operation Return Floor - This adjustment sets the floor that the car
goes to if the pit is flooded, sensor input FPS1.
H18
F/R
0–1
Flooded Pit Sensor 1 Operation Return Door - This adjustment sets the side of doors that
cycle upon arrival at the return floor during Flooded Pit Operation, sensor input FPS1.
Values:
0 = Front
1 = Rear
H19
floor
1–nf
Flooded Pit Sensor 2 Operation Return Floor - This adjustment sets the floor that the car
goes to if the pit is flooded, sensor input FPS2.
H20
F/R
0–1
Flooded Pit Sensor 2 Operation Return Door - This adjustment sets the side of doors that
cycle upon arrival at the return floor during Flooded Pit Operation, sensor input FPS2.
Values:
0 = Front
1 = Rear
H21
sec.
0-30
Flooded Pit Door Open Time - This adjustment sets the door standing time used at the
return floor.
J10
pounds
500–65000
Capacity - The rated car capacity.
J11
—
1–# of cars
Car ID - The car number within a group, beginning with 1. Used by the software for identi-
fication and I/O assignments. See ELD for the designator - used by programs and people
for identification.
Note
: Altering this value may cause some features to malfunction.
J12
—
0–240
Car Communication Number.
Values:
0 = The controller computes the comm number from the car and group number.
1-255 = Force to the selected comm number.
J13
—
1–8
Group ID - The group number within a multiple group network, beginning with 1.
J14
floor
1–nf
Lobby Floor - This adjustment sets the lobby to the proper car opening (beginning with 1 =
bottom floor).
Note
: This floor number may not be the building floor number.
J19
—
0–1
Relevel on the Stop Switch - Permits a re-level with the in Car Stop Switch active and the
CST input not active; Does not permit a re-level for the Fireman's Stop Switch(es).
Values:
0 = No releveling while the Emergency Stop Switch is thrown.
1 = Up releveling only while Emergency Stop Switch is thrown.
J20
—
0–1
Stop Switch Type - This adjustment sets the value to the type of stop switch provided on
this installation.
Values:
0 = Keyed stop switch.
1 = Public access stop switch.
L10
cars
0–ncars
Lobby Elevator Request - Number of cars requested to park at the lobby.
Values:
0 = Disable
1 = Enable
L12
floors
1–nfloors
Lobby - This adjustment sets the designated floor position number for the lobby floor, and
is also used as the homing floor for the lobby elevator request.
L14
floors
1–nfloors
Zone 1 Floor - The car stays at the last floor served for normal operation.
Notes
:
• When parking is enabled and a car becomes free, it will be sent to one of the zone floors
(after a time delay - L25).
• L14 through L19 allow for six different zone or parking floors.
• The number of zone floors used is set by L20.
L15
floors
1–nfloors
Zone 2 Floor - See L14.
L16
floors
1–nfloors
Zone 3 Floor - See L14.
L17
floors
1–nfloors
Zone 4 Floor - See L14.
Adj
(cont.)
Unit
Range
Definition
(cont.)
Содержание ICON 32
Страница 1: ...Controller...
Страница 3: ...INSTALLATION SECTION...
Страница 4: ...INSTALLATION SECTION...
Страница 39: ...ADJUSTMENT SECTION...
Страница 40: ...ADJUSTMENT SECTION...
Страница 42: ...2 2 Vertical Express Printed in USA April 2020 Contents Adjustment Section This page intentionally left blank...
Страница 83: ...DIAGNOSTICS SECTION...
Страница 84: ...DIAGNOSTICS SECTION...
Страница 86: ...3 2 Vertical Express Printed in USA April 2020 Contents Diagnostics Section This page intentionally left blank...
Страница 131: ...TROUBLESHOOTING SECTION...
Страница 132: ...TROUBLESHOOTING SECTION...
Страница 134: ...4 2 Vertical Express Printed in USA April 2020 Contents Troubleshooting Section This page intentionally left blank...
Страница 165: ...SERVICE INFORMATION SECTION...
Страница 166: ...SERVICE INFORMATION SECTION...
Страница 168: ...5 2 Vertical Express Printed in USA April 2020 Contents Service Section This page intentionally left blank...
Страница 205: ...REFERENCE SECTION SERVICE REFERENCE SECTION...
Страница 206: ...REFERENCE SECTION...
Страница 208: ...5R 2 Vertical Express Printed in USA April 2020 Contents Reference Section This page intentionally left blank...