DIAGNOSTICS
Vertical Express Product Manual
3-11
88500 v.1.0
Diagnostics Section
Adjustments
This manual shows only the parameters that have an operational relevance to the ICON32. The UIT may have
additional parameters available, which should not effect the controller operation.
O16
F/R
0–1
Low Oil Door - During low oil operation, this adjustment sets the selective doors to open
when returning to a landing.
Values:
0 = Front
1 = Rear
O17
sec.
20-255
Low Oil Timer - This adjustment sets how long motor is allowed to run before activating the
low oil operation.
Note
: If the floor-to-floor run time exceeds the timer value, the low oil operation actives.
O18
floor
0–nf
Massachusetts Medical Floor - This adjustment sets which landing the car returns to when
Massachusetts Medical Service is activated.
Note
: If a landing does not have front/rear openings (based on the value of O19), the
adjustment will be refused.
O19
F/R
0–1
Massachusetts Medical Door - This adjustment sets the selective door to open landing
return during Massachusetts Medical Recall Service Operation.
Values:
0 = Front
1 = Rear
O20
—
0–1
Independent Overrides Lockouts - This adjustment (when enabled) allows the Car Inde-
pendent Service to override the Car Call Lockouts.
Values:
0 = Disabled
1 = Enabled
O21
floor
2–nf
Hoistway Access Top Floor - This adjustment sets which landing is designated for the top
landing of hoistway access operation.
See also:O11, O22, Z38, and Z39.
O22
inches
0–168
Hoistway Access Top Zone - When the car runs on hoistway access, this zone is the dis-
tance (in inches) above the top hoistway access floor.
Note
: Modifying this parameter requires SP & NP Configuration.
See also: O11, O22, Z38, and Z39.
O23
floor
1–nf
Viscosity Return Floor - This adjustment sets which return floor is used for viscosity opera-
tion.
O24
—
0–1
Transfer Calls on Door Close - This adjustment (if enabled) allows call transfers to occur
while the doors are closing.
Values:
0 = Disabled
1 = Enabled
O28
sec.
5–60
Non-Interference Time - This adjustment sets the delay (in seconds) after the doors close,
and before SAPB calls can be latched. This time delay gives priority to car calls.
O29
sec.
5–30
Jack Resync Lower Time - This adjustment sets the time allowed for a jack resync to be
completed once the car reaches the bottom and begins the resync operation.
O30
—
1-3
Jack Resync Interval - This adjustment sets the number of days between automatic jack
resync operations.
See also: FJR and JRT
O31
floor
1–nf
Jack Resync Landing - This adjustment sets the return landing for jack resync return.
O32
F/R
0–1
Jack Resync Door - This adjustment sets the preferred door to open at the jack
resync return landing during jack resync operation.
Values:
0 = Front
1 = Rear
O33
floor
1–nf
Lobby Recall Return Landing - This adjustment sets the landing that lobby recall will return
to during lobby recall operation.
Adj
(cont.)
Unit
Range
Definition
(cont.)
Содержание ICON 32
Страница 1: ...Controller...
Страница 3: ...INSTALLATION SECTION...
Страница 4: ...INSTALLATION SECTION...
Страница 39: ...ADJUSTMENT SECTION...
Страница 40: ...ADJUSTMENT SECTION...
Страница 42: ...2 2 Vertical Express Printed in USA April 2020 Contents Adjustment Section This page intentionally left blank...
Страница 83: ...DIAGNOSTICS SECTION...
Страница 84: ...DIAGNOSTICS SECTION...
Страница 86: ...3 2 Vertical Express Printed in USA April 2020 Contents Diagnostics Section This page intentionally left blank...
Страница 131: ...TROUBLESHOOTING SECTION...
Страница 132: ...TROUBLESHOOTING SECTION...
Страница 134: ...4 2 Vertical Express Printed in USA April 2020 Contents Troubleshooting Section This page intentionally left blank...
Страница 165: ...SERVICE INFORMATION SECTION...
Страница 166: ...SERVICE INFORMATION SECTION...
Страница 168: ...5 2 Vertical Express Printed in USA April 2020 Contents Service Section This page intentionally left blank...
Страница 205: ...REFERENCE SECTION SERVICE REFERENCE SECTION...
Страница 206: ...REFERENCE SECTION...
Страница 208: ...5R 2 Vertical Express Printed in USA April 2020 Contents Reference Section This page intentionally left blank...