9
20307394
4" x 6
5
⁄
8
" SLP Termination Kit
SLP-RVTM -
HORIZONTAL TERMINATION KIT
Installation Instructions
1. A wall square firestop
MUST BE
installed if the vent
passes through a ceiling or exterior wall. Cut a 9" wide
x 9" high (229 x 229 mm) opening through the exterior
wall or framing. A wall rectangular firestop (not provid-
ed)
MUST BE
installed if the vent passes through inte
-
rior walls. In that case, cut a 10" wide x 10" high (254
x 254 mm) opening through the wall or framing. The
framing members may need to be reinforced. Position
the firestop on the hole previously cut and secure with
screws or nails (not provided). Run vent pipe through
firestop. The gap between the vent pipe and firestop
may be sealed.
2. Attach slip section of cap to last vent section. Maintain
1
1
⁄
2
in. overlap between slip and vent sections. Make
sure the termination cap is installed with the embossed
arrow pointing up.
3. If the house has vinyl siding, mark and cut the vinyl
siding around the pipe so the termination cap can be
mounted flush to the wall. Finish the edges of the sid-
ing with trim or “J channel" and caulking to prevent
water from leaking into the building.
Figure 13
4. Attach the termination cap to the exterior wall using
four (4) screws provided.
Figure 14 - SLP-HSFTK Side View
Termination Cap with
slip section
SLP Inner Flex
Adapter
SLP Outer Flex
Adapter
Flex Pipe 4” x 48”
Flex Pipe 6-5/8” x 48”
Small Hose Clamp
Large Hose Clamp
Screws
Spacer Spring
Exhaust Pipe
Starting Collar
(on unit)
SLP Flex Starter
Figure 13 - SLP-HSFTK
Adapter, Flex to
Slip Section on
Termination Cap
Hose Clamp
Exterior Wall
Sheeting
J-channel (around
termination cap)
Siding
Termination Cap
Outer Flex Pipe
Interior Finish Wall
Firestop
Framing
1” Min.
Install the termination cap to the exterior wall with four
(4) #8 x 3" screws provided. In some installations the
flexible vent may need to pass through the SLP-FS wall
shield firestop. The flexible vent outside diameter exceeds
the diameter of the hole in the SLP-FS. The diameter of
the inner hole of the SLP-FS will need to be increased
from 6-3/4" to 7
1
⁄
4
". This modification can be made by
trimming 1/4" evenly around the circumference of the inner
hole in the SLP-FS. This modification is not required in
installations where the SLP slip section projects through
the SLP-FS.
Install the slip section on the end of the flex onto the collars
on the termination cap. Ensure that the two overlap at least
1
1
⁄
2
". See page 6.
When using aluminum or vinyl siding, finish the edges of
the siding around the termination cap with “J channel" and
caulking to prevent water from leaking into the building.
WARNING
Termination cap must be positioned so the embossed
arrow is pointed up.