background image

DVB Series Direct Vent Gas Fireplace

52

20306740

REPLACEMENT PARTS

STANDING PILOT - MILLIVOLT CONTROL

Fuel Conversion Kits - Millivolt
Natural Gas to LP

 

300DVB 

Kit #BCK300CKPA

 

400DVB 

Kit #BCK400CKPA

 

500DVB 

Kit #BCK500CKPA

LP to Natural Gas

 

300DVB 

Kit #BCK300CKNA

 

400DVB 

Kit #BCK400CKNA

 

500DVB 

Kit #BCK500CKNA

Item Description

Qty.

300DVBNV7 300DVBPV7 400DVBNV7 400DVBPV7 500DVBNV7 500DVBPV7

1.

Gas Valve Assy.

1

37D0117

37D0118

37D0117

37D0118

37D0117

37D0118

2.

Pilot Assembly

1

37D0018

37D0019

37D0018

37D0019

37D0018

37D0019

2C.

Replacement Thermocouple

1

37D1067

37D1067

37D1067

37D1067

37D1067

37D1067

2I.

Replacement Igniter and Wire

1

37D1069

37D1069

37D1069

37D1069

37D1069

37D1069

2T.

Replacement Thermopile

1

37D1068

37D1068

37D1068

37D1068

37D1068

37D1068

3.

Burner Tube

1

54D0288

54D0288

54D0194

54D0194

54D0194

54D0194

4.

Flexhose with Shutoff Valve

1

23D6046

23D6046

23D6046

23D6046

23D6046

23D6046

5.

Rocker Switch

1

41D0048

41D0048

41D0048

41D0048

41D0048

41D0048

6.

Piezo Igniter

1

14D0503

14D0503

14D0503

14D0503

14D0503

14D0503

7.

Injector

1

62D3006

20H3146

62D3004

20H3143

20H3145

57D0210

8.

Burner Assembly

1

54D0200

54D0200

54D0001

54D0001

54D0001

54D0329

9.

Venturi

1

69D1119

69D1026

69D1119

69D1026

69D1119

69D1026

10.

Wire Assembly

1

44D0500

44D0500

44D0500

44D0500

44D0500

44D0500

10.

Wire Assembly

1

44D0501

44D0501

44D0501

44D0501

44D0501

44D0501

Accessories

11.

Thermostatic Remote Control

TSMT, RCST, RCT, RCSTE, RCSTEBK, RCSIT, RCSITEA, WWTD

12.

Remote Control  

On/Off

TSST, RCB, RCMT, RCBE, WMTD

13.

Wall Switch Kit

MVWS

14.

Wall Thermostat Kit

WT

Содержание 300DVB(N/P)(V/SC)7SB

Страница 1: ...alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Thi...

Страница 2: ...ns Installation 21 Fireplace Installation 24 Check Gas Type 24 Installing Gas Piping 25 Installation Millivolt 26 Millivolt Check Gas Pressure 26 Electrical Wiring 27 Remote Wall Switch Installation 2...

Страница 3: ...structions 4 Never install the fireplace in a recreational vehicle where curtains furniture clothing or other flam mable objects are less than 42 from the front top or sides of the fireplace in high t...

Страница 4: ...ested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada as follows LISTED VENTED GAS FIREPLACE HEATER TESTED TO ANSI Z21 88 2014_CSA...

Страница 5: ...t elevations above 4 500 feet 1 370 m GAS PRESSURES Natural Propane LP Inlet Minimum 4 5 w c 11 0 w c Inlet Maximum 10 5 w c 13 0 w c Manifold Pressure 3 5 w c 10 0 w c GAS SPECIFICATIONS ORIFICE SIZE...

Страница 6: ...8 841 mm K 21 8 54 mm 11 4 32 mm 11 4 32 mm L 11 2 38 mm 21 2 64 mm 21 2 64 mm M 15 16 24 mm 15 16 24 mm 15 16 24 mm N 315 8 803 mm 343 4 883 mm 343 4 883 mm O 331 2 851 mm 371 2 953 mm 411 2 1054 mm...

Страница 7: ...all across a corner or use an exterior chase Refer to Figure 3 for suggested locations Location should be out of high traffic areas and away from furniture and draperies due to heat from appli ance Ne...

Страница 8: ...ntel 5 7 11 3 12 8 6 2 FP2204a mantelclearances Wall Stud Standoff FP2204 Top of Exhaust Louvers Side View 1 2 3 4 1 2 45 FP2093A mantel side clearance Wall Combustible Material Area Side of Fire plac...

Страница 9: ...abs Do not use for framing or header Framing Nailing Flange Screws Nailing Flange FP2094a Figure 6 Secure Fireplace to Floor and Framing Studs FINISHING MATERIAL NOTE Any remote wiring i e remote cont...

Страница 10: ...onversion to top vent configuration the 4 102 mm flue pipe should be concentric within the 65 8 175 mm outer collar within 1 4 FP1991 remove screws Screws Flue Pipe Cover Flue Pipe Adapter FP1991 Figu...

Страница 11: ...all instructions completely and thoroughly before attempting installation Failure to do so could result in serious injury property damage or loss of life Operation of improperly installed and maintain...

Страница 12: ...ppliances 100 000 BTU h 30kW 6 15cm for appliances 10 000 BTU h 3kW 9 23cm for appliances 10 000 BTU h 3kW and 50 000 BTU h 15kW 12 30cm for appliances 50 000 BTU h 15kW C Clearance to permanently clo...

Страница 13: ...rmination cap must be a minimum of 3 914 mm below the termination cap 3 All gravity air intakes within 3 914 mm of a termination cap must be a minimum of 1 305 mm below the termination cap GENERAL INF...

Страница 14: ...ine the re lationship between the vertical and horizontal dimensions of the vent system 1 Determine the height of the center of the horizontal vent pipe exiting through the outer wall Using this di me...

Страница 15: ...the flue is acceptable at this point of penetration If vertical rise is 71 2 feet or higher when top venting the clearance to combustibles is 1 on all sides of the horizontal run Vertical sections of...

Страница 16: ...84 100 Vent Opening 2 99 djt Vent Opening for Combustible Walls 95 8 244 mm Min Fireplace Hearth Framing Detail Opening for Noncombustible Wall 71 2 190 mm Fireplace Hearth FP2293 Figure 17 Locate ven...

Страница 17: ...d onto the top edge of the firebox flue adapter To create this open center restrictor twist and break off the center rib of the supplied flue restrictor The installed part should appear similar to tha...

Страница 18: ...P1177 Figure 23 Maximum horizontal run with no rise Example According to the vent graph Page 14 the maximum horizontal vent length in a system with a 71 2 2 3 m rise is 20 6 m and if a 90 elbow is req...

Страница 19: ...wall 95 8 244 mm Min Step 2 Secure firestop to the inside frame center in the 95 8 x 95 8 vent opening Step 3 Place fireplace into position Measure the vertical height X required from the base of the...

Страница 20: ...pring around the pipe and interlock the ends of the spacer spring approximately 2 51 mm Measure 63 4 172 mm from the end of the pipe Place the next spring 5 127 mm from the previously installed spring...

Страница 21: ...the wall 5 Apply high temperature sealant caulking supplied around the 4 and 7 snorkel collars BG402a Top Vent Below grade installation Firestop Screws Minimum 4 Clearance Ground Window Well Gravel D...

Страница 22: ...adapter for optimal flame appearance Figure 36 1 Locate your fireplace 2 Plumb to center of the 4 flue collar from ceiling above and mark position 3 Cut opening equal to 93 4 x 93 4 248 x 248 mm 4 Pr...

Страница 23: ...oof Support Application Typical Ceiling Support Application FP1184 Figure 38 Venting Supports 2 ft Min 2 ft Min X 12 H FP1971 Min chimney clearance Termination Vent Storm Collar Flashing Lowest Discha...

Страница 24: ...n certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA design certified equip ment shutoff valve from your dealer For propane LP co...

Страница 25: ...the gas to the fireplace Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces Apply pipe joint sealant lightly to male threads This will prevent ex...

Страница 26: ...sure and turn captured screw clockwise firmly to reseal Do not over torque Check test points for gas leaks FP1979 Millivolt gas valve FP1979 Figure 43 Gas Pressure Check at Gas Valve Pressure Test IN...

Страница 27: ...nnect wall switch to 110 V circuit Figure 44 Wiring Diagram for Wall Switch OPTIONAL FAN BLOWER SYSTEMS BLOT Installation Instructions Wiring 1 Before installing the blower wire the receptacle into an...

Страница 28: ...a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service techn...

Страница 29: ...t interrupted the gas flow After that period of time when the magnet is closed it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any too...

Страница 30: ...lace This switch allows you to turn on and to turn off the main burner without using the gas valve knob Make sure the button is in the ON position to light the main burner Figure 47 LIGHTING THE BURNE...

Страница 31: ...ng power outages 2 The Signature Command System can also be operated without A C power The system can run on four 4 AA batteries for approximately six 6 months under normal use 3 A C power must be use...

Страница 32: ...wall Do not extend beyond the 15 ft wire cable provided If a longer distance is required the 15 ft may be extended up to 30 ft maximum by using two 2 SCSWEK cables plugged together Route the wire from...

Страница 33: ...tor Sparker Conversion NG LP Plug in Connector Control Board to Command Center OFF LO LED ON HI Master Switch Command Center Optional Wall Switch Plug in Connector Stepper Motor to Control Board DC Po...

Страница 34: ...the control will not work correctly WARNING Electrical connections should only be performed by a qualified licensed electrician Main power supply must be turned off before connecting the fan to the ma...

Страница 35: ...2 MANUAL BLOWER 1 This must be done before framing the fireplace When installing the FK 12 blower a wall switch control must be installed to control the blower 2 The fireplace power supply is wired th...

Страница 36: ...bor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will...

Страница 37: ...smell gas go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame...

Страница 38: ...To Command Center To Stepper Motor To Valve FP1917 Signature components 8 08 Battery Door Master Switch ON LED OFF Control Board Command Center Figure 57 Signature Command System Components Transmitte...

Страница 39: ...tween stand ing pilot and intermittent pilot 2 After the above operation one beep for standing pi lot or two beeps for intermittent pilot will be given as confirmation Six hour Safety Shutdown Option...

Страница 40: ...pilot will stay in inter mittent pilot configuration the pilot will be shut off Turning the Fireplace Off There are three ways to turn the fireplace off 1 Flip the master switch to the off O position...

Страница 41: ...ass frame aside Figure 58 Remove Glass Frame Glass Frame Screen Barrier WARNING Each clamp has a quick spring force When reinstalling clamps keep fingers clear Remove control panel to operate middle c...

Страница 42: ...r LG607 Figure 60 Log Placement 300DVB 400DVB Shown FP2647 DVB rockwool placement Figure 59 Placement of Rock Wool on Burner Cover with Rock Wool Burner FP2647 WARNING The use of too much rock wool co...

Страница 43: ...slots until it fits securely in place NOTICE It is the responsibility of the installer to ensure the barrier is affixed to the fireplace at the time of instal lation Tabs two per side Slots Qty 4 Two...

Страница 44: ...cing fireplace It is recommended that a qualified service technician perform these check ups at the beginning of each heating season BURNER PILOT AND CONTROL COMPARTMENT Keep the control compartment l...

Страница 45: ...ials may be used Handle glass door with care to avoid striking or scratch ing it on hard objects To clean glass door follow Glass Removal procedure outlined in the Final Installation section Film depo...

Страница 46: ...ure on remote control If burner comes on replace remote control Place jumper wire across wire at gas valves terminals marked TH and TP TH If burner comes on wires are faulty or connec tions are bad Re...

Страница 47: ...hrough Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Ch...

Страница 48: ...DVB Series Direct Vent Gas Fireplace 48 20306740 REPLACEMENT PARTS 1 2 3 5 11 6 7 8 10 4 9 540701 DVB parts FIREBOX COMPONENTS...

Страница 49: ...7103K 10 Blower Motor 1 93D0006K 93D0006K 93D0006K 11 Thermostat Sensor for Blower 1 26D2870 26D2870 26D2870 Accessories Field Installed Options 2 Brass Louver 1 L30BR L32BR L36BR 2 Pewter Louver 1 L3...

Страница 50: ...MENT PARTS LOGS 1 2 3 4 540701 DVB log parts Ref Description Qty 300DVB 400DVB 500DVB 1 Rear Log 1 1 54D0122 54D0117 54D0331 2 Bottom Left Log 2 1 54D0123 54D0118 54D0358 3 Bottom Right Log 3 1 54D012...

Страница 51: ...DVB Series Direct Vent Gas Fireplace 20306740 51 REPLACEMENT PARTS STANDING PILOT MILLIVOLT CONTROL 1 2C 2I 2T 2 4 5 6 3 8 9 7 10 11 12 13 14 540701 DVB millivolt parts...

Страница 52: ...1069 2T Replacement Thermopile 1 37D1068 37D1068 37D1068 37D1068 37D1068 37D1068 3 Burner Tube 1 54D0288 54D0288 54D0194 54D0194 54D0194 54D0194 4 Flexhose with Shutoff Valve 1 23D6046 23D6046 23D6046...

Страница 53: ...DVB Series Direct Vent Gas Fireplace 20306740 53 REPLACEMENT PARTS 1 2 3 4 20 5 6 7 8 9 13 14 15 16 17 540701 SC parts 12 SIGNATURE COMMAND SYSTEM...

Страница 54: ...alve Control not shown 1 80D0010 80D0010 80D0010 80D0010 80D0010 80D0010 11 Wire Command Ctr Control Box 2 not shown 1 80D0008 80D0008 80D0008 80D0008 80D0008 80D0008 12 A C Adapter 6 Volt 1 80D0041 8...

Страница 55: ...30 48 Vent Pipe 7TDVP48 48 Vent Pipe 30 pack 7TDVP48 30 Twist Lock Elbows 45 Elbow for Vertical Horizontal Offset 7TDV45 45 Elbow for Vertical Offsets 8 pack 7TDV45 8 90 Elbow for Vertical Horizontal...

Страница 56: ...Termination Pipe 8 pack 7TDVP20 8 10 16 Adjustable Termination Pipe 4 pack 7TDVPA 4 12 18 Adjustable Vent Length 7TDVP1218 35 64 Adjustable Vent Length 7TDVP3564 8 Vent Pipe 4 pack 7TDVP8 4 12 Vent P...

Страница 57: ...tion Cap aluminum 46DVA HSC 2 1 Low Profile Vertical Termination Cap 46DVA VC 980 4DT VC 4DVT 3 6 6 Pipe Length galvanized 46DVA 06 908 4DT 06 4DV6 3 6 9 Pipe Length galvanized 46DVA 09 907 4DT 09 3 6...

Страница 58: ...ays to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed MASSACHUSETTS RESIDENTS ON...

Страница 59: ...The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox bur...

Страница 60: ...n CSA P 4 1 09 EFFICIENCY RATINGS MODEL ENERGUIDE RATINGS FIREPLACE EFFICIENCY PERCENTAGE 300DVBNV7 57 9 300DVBPV7 53 8 300DVBNSC7 61 8 300DVBPSC7 55 7 400DVBNV7 58 4 400DVBPV7 58 5 400DVBNSC7 61 1 40...

Страница 61: ...ed in accordance with this instruction manual Read all instructions before starting installation then follow these instructions carefully to maximize fireplace performance and safety Report damaged pa...

Страница 62: ...nt cap on a regular basis to make sure that no debris is interfering with the airflow Inspect entire venting system to en sure proper function PRE INSTALLATION INFORMATION Before You Start Plan your i...

Страница 63: ...l face toward the appliance Commercial or High rise Applications For installation into a commercial or high rise application All outer pipe joints must be sealed with high tempera ture aluminum foil t...

Страница 64: ...driving two 1 2 in screws through the overlapping portions of the outer flues using the pilot holes see Figure 5 This will secure the slip section to the desired length and prevent it from separating...

Страница 65: ...p see Figure 7 Disassemble Vent Sections To disassemble any two pieces of pipe rotate either section Figure 8 so that the seams on both pipe sections are aligned Figure 9 They can then be carefully pu...

Страница 66: ...zontal Termination Cap Attach slip section of cap to last vent section Maintain 11 2 overlap between slip and vent sections NOTE For installations using black pipe slide the decorative wall thimble ov...

Страница 67: ...r exterior combustible wall Cut a 9 wide x 9 high 229 x 229 mm opening through the wall or framing A wall rectangular firestop MUST BE installed if the vent passes through interior walls In that case...

Страница 68: ...from the termination cap Attach the SLP inner flex adapter to the inner pipe of the slip section for the termination cap using three 3 self tapping 10 screws Attach the SLP outer flex adapter to the...

Страница 69: ...14 SLP HSFTK Side View Termination Cap with slip section SLP Inner Flex Adapter SLP Outer Flex Adapter Flex Pipe 4 x 48 Flex Pipe 6 5 8 x 48 Small Hose Clamp Large Hose Clamp Screws Spacer Spring Exh...

Страница 70: ...e way 3 Pull and extend the inner flexible vent 4 Slide the inner vent onto the adapter collar for a minimum 2 overlap 5 Locate the clamp at approximately 3 4 from the flex end and tighten 6 Secure th...

Страница 71: ...The gap between the vent pipe and firestop may be sealed Figure 2 Minimum Radius for Flex Vent Section Attic Above 9 in 229 mm Hole should measure 9 in x 9 in inside to inside 9 in 229 mm Figure 3 Ins...

Страница 72: ...folded outward on the bottom of the shield to allow attachment to ceiling firestop Bend remaining tabs inward on bottom of shield where it rests on the ceiling firestop to maintain the air space betwe...

Страница 73: ...Roof to Lowest Discharge Opening Caulk the gap between the roof flashing and the outside diameter of the pipe Caulk the perimeter of the flashing where it contacts the roof surface Caulk Pipe Flashing...

Страница 74: ...dimples in the outer collar of the cap into the outer flue of the vent See Figure 11 Termination Cap 1 of 3 Storm Collar Screws Caulk Figure 11Secure with Screws Attaching Flexible Venting to Vertical...

Страница 75: ...pter UL1777 Flex Pipe Flex Adapter Starter Roof Support Refer to Figures 5 6 Firestop Secure Screws 3 Places Equidistant Just Above Gear Clamp Gear Clamp 2 Flexible Pipe and Adapter Outer Collar Overl...

Страница 76: ...149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com...

Отзывы: