DVB Series Direct Vent Gas Fireplace
20306740
27
INSTALLATION - MILLIVOLT
ON
OFF
OPTIONAL REMOTE
WALL SWITCH
ON
OFF
OPTIONAL REMOTE
WALL SWITCH
PILOT
HI
LO
ON
OFF
TH
TP
TH/TP
ON
OFF
RS
FP1980
Dv wiring diagram
White
Black
Blue
Gray
Black
Blue
Black
REMOTE WALL MOUNTED SWITCH
A remote wall switch and up to fifteen (15) feet of 18 Ga.
wire may be used with this appliance. Attach the wall
switch in a junction box at the desired location on the
wall.
Figure 44
. Do not extend beyond the wall switch wire
length provided.
NOTE:
Extended lengths of wire may cause the
fireplace not to function properly. Longer length of
wire is permitted if the wire is made out of larger gauge
(diameter) wire. Always check with local code.
W
ARNING
Do not connect wall switch to (110 V)
circuit.
Figure 44 -
Wiring Diagram for Wall Switch
OPTIONAL FAN/BLOWER SYSTEMS (BLOT)
Installation Instructions
Wiring
1. Before installing the blower, wire the receptacle into an
electrical circuit. This should be done before framing
the fireplace. Wire with minimum 60° C wire in accor-
dance with prevailing codes.
2. Remove the external junction box cover by removing
the screw from the left side of the outside firebox wall.
Junction box was installed at the factory.
3. The junction box cover has a factory installed “romex”
style strain relief connector. After connecting the wires,
route the wire leads through this connector. Refer to
the wiring diagram in
Figure 45
.
BLACK
BLACK
WHITE
GREEN
BLACK
BLACK
BLACK
Receptacle
Junction
Box
120VAC
Optional Thermostatic Switch
Speed Control
FP2101
BDV blower wiring
Receptacle
Junction
Box
120VAC
Optional Thermostatic Switch
Speed Control
Figure 45 -
Blower Wiring Diagram
FP2101a
FP1980